1988PubMedRequires access

[The eccentriplate device on the Dideco Vivacell cell separator for the collection of platelets].

G. Andreu, Alexandrine Gautheron, A Nicod-Tran, C Lecrubier, M Samama

Open publisher page 0 citations

Abstract

When adapted to the Dideco Vivacell cell separator, the eccentriplate system allows preparation of leukocyte-poor platelet concentrates. Results of its use on 84 procedures showed that a mean of 4.51 x 10(11) platelets were removed in less than 2 hours with a particularly low level of leukocyte contamination: 2.6 x 10(8). Study of platelet function showed them to be altered more by eccentriplate than by conventional removal with the same apparatus. Analysis of recirculation in vivo corroborated the functional anomalies observed with all aggregating agents (with the exception of arachidonate). These anomalies were associated with a quantity of platelets collected at the lower limit of French norms: 30% of the concentrates contained less than 4 x 10(11) platelets. These findings indicate the need for improvement in the eccentriplate system.

About this research paper

What this paper is about

When adapted to the Dideco Vivacell cell separator, the eccentriplate system allows preparation of leukocyte-poor platelet concentrates. Results of its use on 84 procedures showed that a mean of 4.51 x 10(11) platelets were removed in less than 2 hours with a particularly low level of leukocyte contamination: 2.6 x 10(8). Study of platelet function showed them to be altered more by eccentriplate than by conventional removal with the same apparatus. Analysis of recirculation in vivo corroborated the functional anomalies observed with all aggregating agents (with the exception of arachidonate). These anomalies were associated with a quantity of platelets collected at the lower limit of French norms: 30% of the concentrates contained less than 4 x 10(11) platelets. These findings indicate the need for improvement in the eccentriplate system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

When adapted to the Dideco Vivacell cell separator, the eccentriplate system allows preparation of leukocyte-poor platelet concentrates. Results of its use on 84 procedures showed that a mean of 4.51 x 10(11) platelets were removed in less than 2 hours with a particularly low level of leukocyte contamination: 2.6 x 10(8). Study of platelet function showed them to be altered more by eccentriplate than by conventional removal with the same apparatus. Analysis of recirculation in vivo corroborated the functional anomalies observed with all aggregating agents (with the exception of arachidonate). These anomalies were associated with a quantity of platelets collected at the lower limit of French norms: 30% of the concentrates contained less than 4 x 10(11) platelets. These findings indicate the need for improvement in the eccentriplate system.

Key concepts: Platelet, Medicine, Separator (oil production), In vivo, Immunology, Genetics, Biology, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
[The eccentriplate device on the Dideco Vivacell cell separator for the collection of platelets]. — Research Paper | ScholarLens