2001PubMedRequires access

Simultaneous determination of sixteen phenylurea herbicides in water by high performance liquid chromatography and solid phase extraction.

Li F, Dean A. Martens, A. Kettrup

Open publisher page 3 citations

Abstract

A high performance liquid chromatography (HPLC) procedure for simultaneous determination of sixteen phenylurea herbicides in water is described. A Lichrospher 100 RP-18e column and spectrophotometric detection at 240 nm were used. Adequate retention was achieved with a mobile phase of acetonitrile/water solution with gradient elution. The HPLC analysis time was less than 20 min. The herbicides were isolated from water samples by using a single solid phase extraction procedure with C18 solid-phase columns. An enrichment factor of 1,000 was achieved. Recoveries were in the range between 87.8% and 103.7%. The detection limits of the whole procedure achieved were less than one-tenth of the maximum limit permitted by the European Community standard for drinking water.

About this research paper

What this paper is about

A high performance liquid chromatography (HPLC) procedure for simultaneous determination of sixteen phenylurea herbicides in water is described. A Lichrospher 100 RP-18e column and spectrophotometric detection at 240 nm were used. Adequate retention was achieved with a mobile phase of acetonitrile/water solution with gradient elution. The HPLC analysis time was less than 20 min. The herbicides were isolated from water samples by using a single solid phase extraction procedure with C18 solid-phase columns. An enrichment factor of 1,000 was achieved. Recoveries were in the range between 87.8% and 103.7%. The detection limits of the whole procedure achieved were less than one-tenth of the maximum limit permitted by the European Community standard for drinking water.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high performance liquid chromatography (HPLC) procedure for simultaneous determination of sixteen phenylurea herbicides in water is described. A Lichrospher 100 RP-18e column and spectrophotometric detection at 240 nm were used. Adequate retention was achieved with a mobile phase of acetonitrile/water solution with gradient elution. The HPLC analysis time was less than 20 min. The herbicides were isolated from water samples by using a single solid phase extraction procedure with C18 solid-phase columns. An enrichment factor of 1,000 was achieved. Recoveries were in the range between 87.8% and 103.7%. The detection limits of the whole procedure achieved were less than one-tenth of the maximum limit permitted by the European Community standard for drinking water.

Key concepts: Chromatography, High-performance liquid chromatography, Solid phase extraction, Detection limit, Extraction (chemistry), Chemistry, Elution, Gradient elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of sixteen phenylurea herbicides in water by high performance liquid chromatography and solid phase extraction. — Research Paper | ScholarLens