1998•PubMedRequires access

[Separation and determination of naproxen by reversed-phase high performance liquid chromatography].

Cheng Wang, G W Zou

Open publisher page 1 citations

Abstract

A reversed-phase HPLC method has been developed for the separation and determination of naproxen and its bromo-substituted compound. These compounds were separated on a Shim-pack CLC ODS column (5 microns, 250 mm x 4.6 mm i.d.) by using a methanol-water (80/20, V/V) solution containing 50 mmol/L lactic acid and adjusted to pH 2.5 with perchloric acid as mobile phase, with flow rate of 0.8 mL/min and UV detection at 271 nm. Benzoic acid was selected as an internal standard. At the concentration range of 5-100 mg/L, the linear internal standard working curves with r > 0.9995 were obtained. The accuracy of this method for naproxen and its bromo-substituted compound were 99.83%-102.07% and 99.00%-100.83%, and RSD were < 2.58% and < 3.64% respectively.

About this research paper

What this paper is about

A reversed-phase HPLC method has been developed for the separation and determination of naproxen and its bromo-substituted compound. These compounds were separated on a Shim-pack CLC ODS column (5 microns, 250 mm x 4.6 mm i.d.) by using a methanol-water (80/20, V/V) solution containing 50 mmol/L lactic acid and adjusted to pH 2.5 with perchloric acid as mobile phase, with flow rate of 0.8 mL/min and UV detection at 271 nm. Benzoic acid was selected as an internal standard. At the concentration range of 5-100 mg/L, the linear internal standard working curves with r > 0.9995 were obtained. The accuracy of this method for naproxen and its bromo-substituted compound were 99.83%-102.07% and 99.00%-100.83%, and RSD were < 2.58% and < 3.64% respectively.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reversed-phase HPLC method has been developed for the separation and determination of naproxen and its bromo-substituted compound. These compounds were separated on a Shim-pack CLC ODS column (5 microns, 250 mm x 4.6 mm i.d.) by using a methanol-water (80/20, V/V) solution containing 50 mmol/L lactic acid and adjusted to pH 2.5 with perchloric acid as mobile phase, with flow rate of 0.8 mL/min and UV detection at 271 nm. Benzoic acid was selected as an internal standard. At the concentration range of 5-100 mg/L, the linear internal standard working curves with r > 0.9995 were obtained. The accuracy of this method for naproxen and its bromo-substituted compound were 99.83%-102.07% and 99.00%-100.83%, and RSD were < 2.58% and < 3.64% respectively.

Key concepts: Naproxen, Chromatography, Perchloric acid, Chemistry, High-performance liquid chromatography, Methanol, Benzoic acid, Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
[Separation and determination of naproxen by reversed-phase high performance liquid chromatography]. — Research Paper | ScholarLens