[Discrimination of novel influenza A (H1N1) and influenza A and influenza B viruses using a single-tube multiplex RT-real time PCR].
Hong Zhang, Yongqiang He, Yanjun Zhang, Zhen Wang, Zhen Li
Abstract
Hong Zhang, Yongqiang He, Yanjun Zhang, Zhen Wang, Zhen Li
Abstract
OBJECTIVE: To establish and evaluate a single-tube multiplex RT-real time PCR assay for detecting novel influenza A H1N1, influenza A and influenza B viruses (called "IV" for short) simultaneously. METHODS: A total of 213 clinical specimens of influenza-like patient's throat swab were collected during October 2010 and April 2011. 152 bp fragment in HA gene of novel influenza A H1N1 virus, 128 bp fragment in M gene of influenza A virus and 107 bp fragment in NP gene of influenza B virus were chosen as the target genes for multiplex RT-real time PCR, a specific primers and probes labeled with different fluoresceins were designed. The standard plasmid was constructed using in vitro transcription assay, and the standard curve was established. The reproducibility, specificity and sensitivity of the assay were evaluated. Furthermore, RNA extracted from 213 clinical specimens of throat swab was detected and verified by sequencing. RESULTS: The corresponding standard curves of novel influenza A H1N1 virus, influenza A virus and influenza B virus were Y = - 3.46 lgX + 46.985, Y = - 3.49 lgX + 37.709, Y = - 3.51 lgX + 38.889, respectively; Y was cycle threshold (Ct), and lgX was logarithm value of virus replication number. The standard curve coefficient was 0.998. The detection limit of this assay was 10(2) copies/microl in one reaction. The specificity was strong. 39 (18.3%), 63 (29.6%) and 23 (10.8%) of 213 clinical specimens detected were positive for novel influenza A H1N1 virus RNA,influenza A virus RNA and influenza B virus RNA respectively. The positive samples were verified by sequencing. CONCLUSION: The single-tube multiplex RT-real time PCR assay developed in this study for detecting and identifying novel influenza A H1N1, influenza A and influenza B viruses simultaneously was rapid, specific and sensitive.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To establish and evaluate a single-tube multiplex RT-real time PCR assay for detecting novel influenza A H1N1, influenza A and influenza B viruses (called "IV" for short) simultaneously. METHODS: A total of 213 clinical specimens of influenza-like patient's throat swab were collected during October 2010 and April 2011. 152 bp fragment in HA gene of novel influenza A H1N1 virus, 128 bp fragment in M gene of influenza A virus and 107 bp fragment in NP gene of influenza B virus were chosen as the target genes for multiplex RT-real time PCR, a specific primers and probes labeled with different fluoresceins were designed. The standard plasmid was constructed using in vitro transcription assay, and the standard curve was established. The reproducibility, specificity and sensitivity of the assay were evaluated. Furthermore, RNA extracted from 213 clinical specimens of throat swab was detected and verified by sequencing. RESULTS: The corresponding standard curves of novel influenza A H1N1 virus, influenza A virus and influenza B virus were Y = - 3.46 lgX + 46.985, Y = - 3.49 lgX + 37.709, Y = - 3.51 lgX + 38.889, respectively; Y was cycle threshold (Ct), and lgX was logarithm value of virus replication number. The standard curve coefficient was 0.998. The detection limit of this assay was 10(2) copies/microl in one reaction. The specificity was strong. 39 (18.3%), 63 (29.6%) and 23 (10.8%) of 213 clinical specimens detected were positive for novel influenza A H1N1 virus RNA,influenza A virus RNA and influenza B virus RNA respectively. The positive samples were verified by sequencing. CONCLUSION: The single-tube multiplex RT-real time PCR assay developed in this study for detecting and identifying novel influenza A H1N1, influenza A and influenza B viruses simultaneously was rapid, specific and sensitive.
Key concepts: Virology, Virus, Multiplex, Influenza A virus, Real-time polymerase chain reaction, Biology, Multiplex polymerase chain reaction, Reverse transcription polymerase chain reaction