PURPOSE: To evaluate the efficacy of the valve implantation for the treatment of neovascular glaucoma. METHODS: 15 cases (15 eyes) neovascular glaucoma were treated with AHMED valve implantation surgery, and followed up for 6 to 42 months. RESULTS: The IOP of the cases is lowered from 6.01 +/- 1.28 kPa (1 kPa = 7.5 mmHg) preoperatively to 1.96 +/- 0.68 kPa postoperatively. The success rate was 80.0% (The criteria of success is 0.80 kPa < or = IOP < or = 2.80 kPa and without severe complication that influence the visual acuity). The common postoperative complications included hyphema, shallow anterior chamber. CONCLUSION: The AHMED valve implantation surgery can lower the IOP, increase the operative success rate and preserve the visual function effectively. It is regarded to be an effective, safe method to treat neovascular glaucoma.

About this research paper

What this paper is about

PURPOSE: To evaluate the efficacy of the valve implantation for the treatment of neovascular glaucoma. METHODS: 15 cases (15 eyes) neovascular glaucoma were treated with AHMED valve implantation surgery, and followed up for 6 to 42 months. RESULTS: The IOP of the cases is lowered from 6.01 +/- 1.28 kPa (1 kPa = 7.5 mmHg) preoperatively to 1.96 +/- 0.68 kPa postoperatively. The success rate was 80.0% (The criteria of success is 0.80 kPa < or = IOP < or = 2.80 kPa and without severe complication that influence the visual acuity). The common postoperative complications included hyphema, shallow anterior chamber. CONCLUSION: The AHMED valve implantation surgery can lower the IOP, increase the operative success rate and preserve the visual function effectively. It is regarded to be an effective, safe method to treat neovascular glaucoma.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the efficacy of the valve implantation for the treatment of neovascular glaucoma. METHODS: 15 cases (15 eyes) neovascular glaucoma were treated with AHMED valve implantation surgery, and followed up for 6 to 42 months. RESULTS: The IOP of the cases is lowered from 6.01 +/- 1.28 kPa (1 kPa = 7.5 mmHg) preoperatively to 1.96 +/- 0.68 kPa postoperatively. The success rate was 80.0% (The criteria of success is 0.80 kPa < or = IOP < or = 2.80 kPa and without severe complication that influence the visual acuity). The common postoperative complications included hyphema, shallow anterior chamber. CONCLUSION: The AHMED valve implantation surgery can lower the IOP, increase the operative success rate and preserve the visual function effectively. It is regarded to be an effective, safe method to treat neovascular glaucoma.

Key concepts: Medicine, Neovascular glaucoma, Hyphema, Glaucoma valve, Surgery, Visual acuity, Glaucoma, Ophthalmology