2009•PubMedRequires access

[Determination of netilmicin in rat plasma by reversed-phase high performance liquid chromatography with fluorescence detection and pre-column derivatization].

Xiaojuan Chang, Jingdong Peng, Shaopu Liu, Limin Liu, Yongkuang Dai

Open publisher page 2 citations

Abstract

A new, simple and sensitive method based on pre-column derivatization by reversed-phase high performance liquid chromatography (HPLC) is described for the separation and quantification of netilmicin in plasma, using 9-fluorenylmethyl chloroformate (FMOC-Cl) as the derivatization reagent. Its pharmacokinetics is also presented. The derivatization modes and chromatographic conditions were optimized. The separation was performed on an Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm, 5 microm) with a mixture of water-acetonitrile (15:85, v/v) as mobile phase and the flow rate was 1.0 mL/min. The excitation wavelength was 265 nm and the emission wavelength was 315 nm. The linear range was 0.045-8.88 mg/L and the correlation coefficient (r) was 0.9993. The limit of detection (LOD) (S/N = 3) was about 0.01 mg/L, and the limit of quantification was 0.03 mg/L (3LOD) for netilmicin. The relative standard deviation was less than 3% for intra-day assay (n = 5) and 3.5% for inter-day assay (n = 5) and the relative recovery was in the range of 96.62%-100.84% (n = 3). The plasma volume of 30 microL was sufficient for the determination of netilmicin. The method provides a reliable bioanalytical methodology to carry out netilmicin pharmacokinetics in rat plasma.

About this research paper

What this paper is about

A new, simple and sensitive method based on pre-column derivatization by reversed-phase high performance liquid chromatography (HPLC) is described for the separation and quantification of netilmicin in plasma, using 9-fluorenylmethyl chloroformate (FMOC-Cl) as the derivatization reagent. Its pharmacokinetics is also presented. The derivatization modes and chromatographic conditions were optimized. The separation was performed on an Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm, 5 microm) with a mixture of water-acetonitrile (15:85, v/v) as mobile phase and the flow rate was 1.0 mL/min. The excitation wavelength was 265 nm and the emission wavelength was 315 nm. The linear range was 0.045-8.88 mg/L and the correlation coefficient (r) was 0.9993. The limit of detection (LOD) (S/N = 3) was about 0.01 mg/L, and the limit of quantification was 0.03 mg/L (3LOD) for netilmicin. The relative standard deviation was less than 3% for intra-day assay (n = 5) and 3.5% for inter-day assay (n = 5) and the relative recovery was in the range of 96.62%-100.84% (n = 3). The plasma volume of 30 microL was sufficient for the determination of netilmicin. The method provides a reliable bioanalytical methodology to carry out netilmicin pharmacokinetics in rat plasma.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new, simple and sensitive method based on pre-column derivatization by reversed-phase high performance liquid chromatography (HPLC) is described for the separation and quantification of netilmicin in plasma, using 9-fluorenylmethyl chloroformate (FMOC-Cl) as the derivatization reagent. Its pharmacokinetics is also presented. The derivatization modes and chromatographic conditions were optimized. The separation was performed on an Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm, 5 microm) with a mixture of water-acetonitrile (15:85, v/v) as mobile phase and the flow rate was 1.0 mL/min. The excitation wavelength was 265 nm and the emission wavelength was 315 nm. The linear range was 0.045-8.88 mg/L and the correlation coefficient (r) was 0.9993. The limit of detection (LOD) (S/N = 3) was about 0.01 mg/L, and the limit of quantification was 0.03 mg/L (3LOD) for netilmicin. The relative standard deviation was less than 3% for intra-day assay (n = 5) and 3.5% for inter-day assay (n = 5) and the relative recovery was in the range of 96.62%-100.84% (n = 3). The plasma volume of 30 microL was sufficient for the determination of netilmicin. The method provides a reliable bioanalytical methodology to carry out netilmicin pharmacokinetics in rat plasma.

Key concepts: Chemistry, Chromatography, Derivatization, Detection limit, High-performance liquid chromatography, Chloroformate, Netilmicin, Reagent

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of netilmicin in rat plasma by reversed-phase high performance liquid chromatography with fluorescence detection and pre-column derivatization]. — Research Paper | ScholarLens