1997PubMedRequires access

[Determination of 5-fluorouracil in human serum by high performance liquid chromatography].

D Wang, Jing Xie

Open publisher page 0 citations

Abstract

A reversed-phase HPLC method is described for determination of 5-fluorouracil in human serum. After being extracted with ethyl acetate 5-fluorouracil was analyzed by reversed-phase HPLC column (Zorbax ODS) and UV-detector (273nm) with tegaful as internal standard. The mobile phase was a mixture of methyl alcohol and water (20:80, V:V) at a flow rate of 1mL/min. The linear range was 0.04-50mg/L (r=0.9990) and the detectable limit was 10ng/mL. The average recovery was 96.85% and the coefficients of variation were 4.38% and 5.37% for within-day and day-to-day tests respectively.

About this research paper

What this paper is about

A reversed-phase HPLC method is described for determination of 5-fluorouracil in human serum. After being extracted with ethyl acetate 5-fluorouracil was analyzed by reversed-phase HPLC column (Zorbax ODS) and UV-detector (273nm) with tegaful as internal standard. The mobile phase was a mixture of methyl alcohol and water (20:80, V:V) at a flow rate of 1mL/min. The linear range was 0.04-50mg/L (r=0.9990) and the detectable limit was 10ng/mL. The average recovery was 96.85% and the coefficients of variation were 4.38% and 5.37% for within-day and day-to-day tests respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reversed-phase HPLC method is described for determination of 5-fluorouracil in human serum. After being extracted with ethyl acetate 5-fluorouracil was analyzed by reversed-phase HPLC column (Zorbax ODS) and UV-detector (273nm) with tegaful as internal standard. The mobile phase was a mixture of methyl alcohol and water (20:80, V:V) at a flow rate of 1mL/min. The linear range was 0.04-50mg/L (r=0.9990) and the detectable limit was 10ng/mL. The average recovery was 96.85% and the coefficients of variation were 4.38% and 5.37% for within-day and day-to-day tests respectively.

Key concepts: High-performance liquid chromatography, Chromatography, Detection limit, Alcohol, Chemistry, Ethyl acetate, Fluorouracil, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of 5-fluorouracil in human serum by high performance liquid chromatography]. — Research Paper | ScholarLens