2001PubMedRequires access

[Determination of trace iodine based on kinetic-spectrophotometry with malachite green-chloramine T system].

Jianguo Li, Wei Yq, Kuo-Shein Shen

Open publisher page 0 citations

Abstract

In this paper, a new kinetic-spectrophotometric method for the determination of trace amount of iodine has been proposed. It is based on the iodine catalysed the reaction of malachite green oxidized by chloramine T in hydrochloric acid medium. The method is sensitive, simple and with good selectivity. The linear range of determination of iodine is 0-48 micrograms.L-1, the detection limit is 4.9 x 10(-10) g.mL-1. The method has been used for the determination of trace amount of iodine in food with satisfactory results.

About this research paper

What this paper is about

In this paper, a new kinetic-spectrophotometric method for the determination of trace amount of iodine has been proposed. It is based on the iodine catalysed the reaction of malachite green oxidized by chloramine T in hydrochloric acid medium. The method is sensitive, simple and with good selectivity. The linear range of determination of iodine is 0-48 micrograms.L-1, the detection limit is 4.9 x 10(-10) g.mL-1. The method has been used for the determination of trace amount of iodine in food with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a new kinetic-spectrophotometric method for the determination of trace amount of iodine has been proposed. It is based on the iodine catalysed the reaction of malachite green oxidized by chloramine T in hydrochloric acid medium. The method is sensitive, simple and with good selectivity. The linear range of determination of iodine is 0-48 micrograms.L-1, the detection limit is 4.9 x 10(-10) g.mL-1. The method has been used for the determination of trace amount of iodine in food with satisfactory results.

Key concepts: Malachite green, Iodine, Detection limit, Chemistry, Linear range, Spectrophotometry, Hydrochloric acid, Chloramine-T

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of trace iodine based on kinetic-spectrophotometry with malachite green-chloramine T system]. — Research Paper | ScholarLens