1983•Journal of Applied PhysiologyRequires access

A new method for measurement of respiratory resistance

Chen‐Fu Shaw, S. T. Chiang, Yuan-Ching Hsieh, Joseph Milic‐Emili, Claude J. M. Lenfant

Open publisher page 17 citations

Abstract

A new method for measuring the resistance of the total respiratory system is presented. The method uses a device comprising a solenoid valve, a multiperforated plate, and a pneumotachograph. The multiperforated plate serves as a constant resistor (Rk) that is used to partially occlude the airway opening, thus rapidly and briefly reducing airflow during natural expiration. If it is assumed that the driving pressure remains constant during the very short period the airway is partially occluded, the respiratory flow immediately preceding the addition of Rk (V) and the flow reduction during partial occlusion (delta V) allow calculation of the resistance of the total respiratory system. The resistance of 14 normal subjects and 18 patients with chronic obstructive pulmonary disease (COPD) was measured with this new method as well as with the body plethysmographic method: 90% of the interrupter values fell within +/- 0.6 cmH2O . l-1.s of the plethysmographic values, and all fell within +/- 0.8 cmH2O . l-1.s.

About this research paper

What this paper is about

A new method for measuring the resistance of the total respiratory system is presented. The method uses a device comprising a solenoid valve, a multiperforated plate, and a pneumotachograph. The multiperforated plate serves as a constant resistor (Rk) that is used to partially occlude the airway opening, thus rapidly and briefly reducing airflow during natural expiration. If it is assumed that the driving pressure remains constant during the very short period the airway is partially occluded, the respiratory flow immediately preceding the addition of Rk (V) and the flow reduction during partial occlusion (delta V) allow calculation of the resistance of the total respiratory system. The resistance of 14 normal subjects and 18 patients with chronic obstructive pulmonary disease (COPD) was measured with this new method as well as with the body plethysmographic method: 90% of the interrupter values fell within +/- 0.6 cmH2O . l-1.s of the plethysmographic values, and all fell within +/- 0.8 cmH2O . l-1.s.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for measuring the resistance of the total respiratory system is presented. The method uses a device comprising a solenoid valve, a multiperforated plate, and a pneumotachograph. The multiperforated plate serves as a constant resistor (Rk) that is used to partially occlude the airway opening, thus rapidly and briefly reducing airflow during natural expiration. If it is assumed that the driving pressure remains constant during the very short period the airway is partially occluded, the respiratory flow immediately preceding the addition of Rk (V) and the flow reduction during partial occlusion (delta V) allow calculation of the resistance of the total respiratory system. The resistance of 14 normal subjects and 18 patients with chronic obstructive pulmonary disease (COPD) was measured with this new method as well as with the body plethysmographic method: 90% of the interrupter values fell within +/- 0.6 cmH2O . l-1.s of the plethysmographic values, and all fell within +/- 0.8 cmH2O . l-1.s.

Key concepts: Plethysmograph, Expiration, Respiratory system, Airway resistance, Exhalation, Pulmonary gas pressures, Medicine, COPD

Related papers

Back to paper searchBrowse research topicsOriginal source
A new method for measurement of respiratory resistance — Research Paper | ScholarLens