2011•PubMedRequires access

In vivo virtual histology intravascular ultrasound comparison of neointimal hyperplasia within drug-eluting- versus bare metal stents.

Kohei Wakabayashi, Gary S. Mintz, Cédric Delhaye, Yu Jeong Choi, Joon‐Hyung Doh, Itsik Ben‐Dor, Michele Gaglia, Rajbabu Pakala, William O. Suddath, Lowell F. Satler, Kenneth M. Kent, Augusto Pichard, Neil J. Weissman, Ron Waksman

Open publisher page 6 citations

Abstract

BACKGROUND: The process of in-stent neointimal hyperplasia (NIH) between drug-eluting stents (DES) and bare metal stents (BMS) might be different. We compared in vivo composition of in-stent NIH between DES and BMS using virtual histology-intravascular ultrasound (VH-IVUS). METHODS AND RESULTS: Volumetric VH-IVUS was used to compare in-stent NIH between 23 DES and 15 BMS in 30 patients who underwent coronary angiography because of angina. The inner and outer VH-IVUS contours were drawn in a way to avoid the stent strut artifacts. Cross-sectional analysis was done at every VH-IVUS frame within the stent, thereby allowing volumetric measurement of stent, lumen, and NIH and its components. Baseline characteristics and IVUS measurements were similar between DES and BMS groups. The duration of follow-up was similar between DES (median 38 months [interquartile range, 7-59]) vs. BMS (median 40 months [interquartile range, 7-99]), (p=0.26). % necrotic core (NC) volume was significantly higher in DES than BMS: 19.5 [16.3, 25.6] vs. 12.1 [8.2, 18.5] (p=0.006). %NC volume significantly increased with time in BMS (p=0.007), but not in DES (p=0.24) so that at any given time point, %NC in DES was greater than in BMS. After adjustment for baseline differences, only DES (p=0.003) and stent age (p=0.043) were independent predictors of %NC volume. VH-IVUS in-stent thin-cap fibroatheromas were detected only in the DES group: 34.8% vs. 0%, p=0.013. CONCLUSION: In vivo composition of in-stent NIH between DES and BMS was different, suggesting that the process of in-stent NIH in DES and BMS is diverse.

About this research paper

What this paper is about

BACKGROUND: The process of in-stent neointimal hyperplasia (NIH) between drug-eluting stents (DES) and bare metal stents (BMS) might be different. We compared in vivo composition of in-stent NIH between DES and BMS using virtual histology-intravascular ultrasound (VH-IVUS). METHODS AND RESULTS: Volumetric VH-IVUS was used to compare in-stent NIH between 23 DES and 15 BMS in 30 patients who underwent coronary angiography because of angina. The inner and outer VH-IVUS contours were drawn in a way to avoid the stent strut artifacts. Cross-sectional analysis was done at every VH-IVUS frame within the stent, thereby allowing volumetric measurement of stent, lumen, and NIH and its components. Baseline characteristics and IVUS measurements were similar between DES and BMS groups. The duration of follow-up was similar between DES (median 38 months [interquartile range, 7-59]) vs. BMS (median 40 months [interquartile range, 7-99]), (p=0.26). % necrotic core (NC) volume was significantly higher in DES than BMS: 19.5 [16.3, 25.6] vs. 12.1 [8.2, 18.5] (p=0.006). %NC volume significantly increased with time in BMS (p=0.007), but not in DES (p=0.24) so that at any given time point, %NC in DES was greater than in BMS. After adjustment for baseline differences, only DES (p=0.003) and stent age (p=0.043) were independent predictors of %NC volume. VH-IVUS in-stent thin-cap fibroatheromas were detected only in the DES group: 34.8% vs. 0%, p=0.013. CONCLUSION: In vivo composition of in-stent NIH between DES and BMS was different, suggesting that the process of in-stent NIH in DES and BMS is diverse.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The process of in-stent neointimal hyperplasia (NIH) between drug-eluting stents (DES) and bare metal stents (BMS) might be different. We compared in vivo composition of in-stent NIH between DES and BMS using virtual histology-intravascular ultrasound (VH-IVUS). METHODS AND RESULTS: Volumetric VH-IVUS was used to compare in-stent NIH between 23 DES and 15 BMS in 30 patients who underwent coronary angiography because of angina. The inner and outer VH-IVUS contours were drawn in a way to avoid the stent strut artifacts. Cross-sectional analysis was done at every VH-IVUS frame within the stent, thereby allowing volumetric measurement of stent, lumen, and NIH and its components. Baseline characteristics and IVUS measurements were similar between DES and BMS groups. The duration of follow-up was similar between DES (median 38 months [interquartile range, 7-59]) vs. BMS (median 40 months [interquartile range, 7-99]), (p=0.26). % necrotic core (NC) volume was significantly higher in DES than BMS: 19.5 [16.3, 25.6] vs. 12.1 [8.2, 18.5] (p=0.006). %NC volume significantly increased with time in BMS (p=0.007), but not in DES (p=0.24) so that at any given time point, %NC in DES was greater than in BMS. After adjustment for baseline differences, only DES (p=0.003) and stent age (p=0.043) were independent predictors of %NC volume. VH-IVUS in-stent thin-cap fibroatheromas were detected only in the DES group: 34.8% vs. 0%, p=0.013. CONCLUSION: In vivo composition of in-stent NIH between DES and BMS was different, suggesting that the process of in-stent NIH in DES and BMS is diverse.

Key concepts: Medicine, Intravascular ultrasound, Stent, Interquartile range, Neointimal hyperplasia, Drug-eluting stent, Bare-metal stent, Lumen (anatomy)

Related papers

Back to paper searchBrowse research topicsOriginal source
In vivo virtual histology intravascular ultrasound comparison of neointimal hyperplasia within drug-eluting- versus bare metal stents. — Research Paper | ScholarLens