Renal 131I-hippurate clearance overestimates true renal blood flow in the instrumented conscious dog
C. Visscher, Dick de Zeeuw, Gerjan Navis, Annie K. van Zanten, Paul E. de Jong, R. M. Huisman
Abstract
C. Visscher, Dick de Zeeuw, Gerjan Navis, Annie K. van Zanten, Paul E. de Jong, R. M. Huisman
Abstract
We evaluated renal 131I-hippurate clearance (ERPFhip) as a measure of renal blood flow (RBF) in chronically instrumented conscious dogs. When adjusted for renal hippurate extraction (Ehip, 0.77 +/- 0.01) and hematocrit (Hct, 39.7 +/- 1%), calculated RBFhip (656 +/- 37 ml/min) markedly exceeded renal blood flow measured with renal artery blood flow probes (RBFprobe, 433 +/- 27 ml/min). The discrepancy could not be explained by flow probe calibration, because in vivo comparison of flow probe values with renal venous outflow showed only a slight underestimation of renal blood flow (slope 0.93, 95% confidence interval 0.89-0.97). Redistribution of hippurate from erythrocytes into renal venous plasma during or shortly after blood sampling led to an underestimation of Ehip by 4 +/- 1% and thus could only explain a small part of the difference. Extrarenal hippurate clearance was excluded, because the amount of 131I-hippurate cleared from plasma equaled that appearing in the urine (303 +/- 17 and 307 +/- 17 ml/min). Applying these corrections, we found that RBFhip still exceeded RBFprobe by 37 +/- 3%. These data indicate that renal blood flow measured by the hippurate clearance technique markedly overestimates true renal blood flow. Because other errors were excluded, a combination of sampling of nonrenal blood and intrarenal hippurate extraction from erythrocytes might play a role.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We evaluated renal 131I-hippurate clearance (ERPFhip) as a measure of renal blood flow (RBF) in chronically instrumented conscious dogs. When adjusted for renal hippurate extraction (Ehip, 0.77 +/- 0.01) and hematocrit (Hct, 39.7 +/- 1%), calculated RBFhip (656 +/- 37 ml/min) markedly exceeded renal blood flow measured with renal artery blood flow probes (RBFprobe, 433 +/- 27 ml/min). The discrepancy could not be explained by flow probe calibration, because in vivo comparison of flow probe values with renal venous outflow showed only a slight underestimation of renal blood flow (slope 0.93, 95% confidence interval 0.89-0.97). Redistribution of hippurate from erythrocytes into renal venous plasma during or shortly after blood sampling led to an underestimation of Ehip by 4 +/- 1% and thus could only explain a small part of the difference. Extrarenal hippurate clearance was excluded, because the amount of 131I-hippurate cleared from plasma equaled that appearing in the urine (303 +/- 17 and 307 +/- 17 ml/min). Applying these corrections, we found that RBFhip still exceeded RBFprobe by 37 +/- 3%. These data indicate that renal blood flow measured by the hippurate clearance technique markedly overestimates true renal blood flow. Because other errors were excluded, a combination of sampling of nonrenal blood and intrarenal hippurate extraction from erythrocytes might play a role.
Key concepts: Extraction ratio, PAH clearance, Renal blood flow, Clearance, Hematocrit, Blood flow, Urology, Effective renal plasma flow