Based on visual inspection, available records, calculations, past operational performance, and according to criteria established for these studies, Wildwood Lake Dam is judged to be in fair condition. Based on the size and hazard classification of the dam, the Spillway Design Flood (SDF) at the dam varies between 1/2 the Probable Maximum Flood (PMF) and the PMF. Based on the downstream conditions, the selected SDF is the PMF. Under existing conditions, the spillway will pass about 48 percent of the PMF without overtopping of the dam. It is judged that the dam could withstand the depth and duration of overtopping that would occur during the 1/2 PMF. If the low areas on the top of the dam were filled to the design elevation, the spillway would pass about 62 percent of the PMF without any overtopping. For either condition, the spillway capacity is rated as inadequate.

About this research paper

What this paper is about

Based on visual inspection, available records, calculations, past operational performance, and according to criteria established for these studies, Wildwood Lake Dam is judged to be in fair condition. Based on the size and hazard classification of the dam, the Spillway Design Flood (SDF) at the dam varies between 1/2 the Probable Maximum Flood (PMF) and the PMF. Based on the downstream conditions, the selected SDF is the PMF. Under existing conditions, the spillway will pass about 48 percent of the PMF without overtopping of the dam. It is judged that the dam could withstand the depth and duration of overtopping that would occur during the 1/2 PMF. If the low areas on the top of the dam were filled to the design elevation, the spillway would pass about 62 percent of the PMF without any overtopping. For either condition, the spillway capacity is rated as inadequate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on visual inspection, available records, calculations, past operational performance, and according to criteria established for these studies, Wildwood Lake Dam is judged to be in fair condition. Based on the size and hazard classification of the dam, the Spillway Design Flood (SDF) at the dam varies between 1/2 the Probable Maximum Flood (PMF) and the PMF. Based on the downstream conditions, the selected SDF is the PMF. Under existing conditions, the spillway will pass about 48 percent of the PMF without overtopping of the dam. It is judged that the dam could withstand the depth and duration of overtopping that would occur during the 1/2 PMF. If the low areas on the top of the dam were filled to the design elevation, the spillway would pass about 62 percent of the PMF without any overtopping. For either condition, the spillway capacity is rated as inadequate.

Key concepts: Spillway, Flood myth, Hydrology (agriculture), Dam failure, Environmental science, Arch dam, Elevation (ballistics), Dam break

Related papers

Back to paper searchBrowse research topicsOriginal source
National Dam Inspection Program. Wildwood Lake Dam (NDI ID Number PA-00157, DER ID Number 64-30), Delaware River Basin, Ariel Creek, Wayne County, Pennsylvania. Phase I inspection report, — Research Paper | ScholarLens