2006PubMedOpen access

Determination of cadmium in wine by electrothermal atomic absorption spectrometry.

Julijana Cvetković, Sonja Arpadjan, Irina Karadjova, Trajče Stafilov

Open full text 18 citations

Abstract

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg L(-1) Cd ranged from 1 to 7%. The accuracy of the method was confirmed by comparing the current results with those found for wet digested wine samples and by the analysis of spiked samples. By applying the proposed method it was found that the cadmium concentration in Macedonian wines ranges from 0.10 to 0.90 microg L(-1).

Open-access reader

About this research paper

What this paper is about

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg L(-1) Cd ranged from 1 to 7%. The accuracy of the method was confirmed by comparing the current results with those found for wet digested wine samples and by the analysis of spiked samples. By applying the proposed method it was found that the cadmium concentration in Macedonian wines ranges from 0.10 to 0.90 microg L(-1).

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg L(-1) Cd ranged from 1 to 7%. The accuracy of the method was confirmed by comparing the current results with those found for wet digested wine samples and by the analysis of spiked samples. By applying the proposed method it was found that the cadmium concentration in Macedonian wines ranges from 0.10 to 0.90 microg L(-1).

Key concepts: Cadmium, Wine, Detection limit, Atomic absorption spectroscopy, Chemistry, Pyrolytic carbon, Relative standard deviation, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of cadmium in wine by electrothermal atomic absorption spectrometry. — Research Paper | ScholarLens