[Consecutive spectrophotometric determinations in one cuvette: a new approach for checking the accuracy of single, profile and emergency determination (author's transl)].

Eisenwiener Hg, J. M. Kindbeiter

Open publisher page 0 citations

Abstract

A cost effective method for emergency and single assays is presented. By this method, a serial (consecutive) determination of reagent blank, sample, standard, and control serum is performed in one single cuvette and with only one pipetting of reagent. Compared to a sequential determination of sample, standard, and control serum, this is specially economical with regard to reagents and cuvettes. A particular application is seen in the field of prefilled cuvette tests, where the consecutive method allows analysis in the sample and in the control serum, and determination of the required standard absorption in a single test. The results found in the determination of glucose and of aspartate aminotransferase show that the consecutive measuring principle is feasible and even results in a more expressive control of accuracy. If the value found in the assay exceeds the measuring range due to too high a substance concentration or activity, or for photometry reasons, it is immediately seen from the incorrect value for the control serum. The same is not possible in the conventional technique, as it uses two separate tests for the sample and for the control serum.

About this research paper

What this paper is about

A cost effective method for emergency and single assays is presented. By this method, a serial (consecutive) determination of reagent blank, sample, standard, and control serum is performed in one single cuvette and with only one pipetting of reagent. Compared to a sequential determination of sample, standard, and control serum, this is specially economical with regard to reagents and cuvettes. A particular application is seen in the field of prefilled cuvette tests, where the consecutive method allows analysis in the sample and in the control serum, and determination of the required standard absorption in a single test. The results found in the determination of glucose and of aspartate aminotransferase show that the consecutive measuring principle is feasible and even results in a more expressive control of accuracy. If the value found in the assay exceeds the measuring range due to too high a substance concentration or activity, or for photometry reasons, it is immediately seen from the incorrect value for the control serum. The same is not possible in the conventional technique, as it uses two separate tests for the sample and for the control serum.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A cost effective method for emergency and single assays is presented. By this method, a serial (consecutive) determination of reagent blank, sample, standard, and control serum is performed in one single cuvette and with only one pipetting of reagent. Compared to a sequential determination of sample, standard, and control serum, this is specially economical with regard to reagents and cuvettes. A particular application is seen in the field of prefilled cuvette tests, where the consecutive method allows analysis in the sample and in the control serum, and determination of the required standard absorption in a single test. The results found in the determination of glucose and of aspartate aminotransferase show that the consecutive measuring principle is feasible and even results in a more expressive control of accuracy. If the value found in the assay exceeds the measuring range due to too high a substance concentration or activity, or for photometry reasons, it is immediately seen from the incorrect value for the control serum. The same is not possible in the conventional technique, as it uses two separate tests for the sample and for the control serum.

Key concepts: Cuvette, Reagent, Pipette, Chromatography, Sample (material), Chemistry, Photometry (optics), Standard solution

Related papers

Back to paper searchBrowse research topicsOriginal source
[Consecutive spectrophotometric determinations in one cuvette: a new approach for checking the accuracy of single, profile and emergency determination (author's transl)]. — Research Paper | ScholarLens