Improved sample and reagent pipetting with the MINILAB.

I. Lindahl, Pierre Masson

Open publisher page 4 citations

Abstract

MINILAB is a small photometer designed for use in small labs and physicians' offices. The instrument is preprogrammed for the determination of several analytes either in whole blood, plasma or serum. Each method is provided as a kit containing disposable cuvettes and capillaries for sample or reagent addition. We examined the precision of the MINILAB using the cholesterol and bilirubin methods for serum, following the recommendations provided for each method, and found that the precisions were not acceptable (CV up to 16% for cholesterol and 43% for bilirubin). Suspecting that these variations were due to sample and reagent pipetting, we tried a simple modification using a Microcap for pipetting and were able to improve the precisions, resulting in CVs of 1.4% for cholesterol and 3.5% for bilirubin.

About this research paper

What this paper is about

MINILAB is a small photometer designed for use in small labs and physicians' offices. The instrument is preprogrammed for the determination of several analytes either in whole blood, plasma or serum. Each method is provided as a kit containing disposable cuvettes and capillaries for sample or reagent addition. We examined the precision of the MINILAB using the cholesterol and bilirubin methods for serum, following the recommendations provided for each method, and found that the precisions were not acceptable (CV up to 16% for cholesterol and 43% for bilirubin). Suspecting that these variations were due to sample and reagent pipetting, we tried a simple modification using a Microcap for pipetting and were able to improve the precisions, resulting in CVs of 1.4% for cholesterol and 3.5% for bilirubin.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

MINILAB is a small photometer designed for use in small labs and physicians' offices. The instrument is preprogrammed for the determination of several analytes either in whole blood, plasma or serum. Each method is provided as a kit containing disposable cuvettes and capillaries for sample or reagent addition. We examined the precision of the MINILAB using the cholesterol and bilirubin methods for serum, following the recommendations provided for each method, and found that the precisions were not acceptable (CV up to 16% for cholesterol and 43% for bilirubin). Suspecting that these variations were due to sample and reagent pipetting, we tried a simple modification using a Microcap for pipetting and were able to improve the precisions, resulting in CVs of 1.4% for cholesterol and 3.5% for bilirubin.

Key concepts: Pipette, Cuvette, Reagent, Chromatography, Bilirubin, Analyte, Chemistry, Medicine