1991PubMedRequires access

[The sensitization of acoustic stapedius reflex].

Xiaoling Yi

Open publisher page 1 citations

Abstract

The acoustic stapedius reflex, which normally occurs at a hearing level of about 85 dB, can be detected at lower levels by means of sensitization. The technique is to apply reflex-eliciting tone and the facilitating tone stimulation. The high-frequency acoustic stapedius reflex can then be detected in this procedure under low-frequency facilitating. When hearing is normal, significant difference can be demonstrated between conventional and facilitated reflex threshold. There is a great amount of reflex threshold improvement with sensitization. Sensorineural hearing loss allowed small or no reflex threshold change with sensitization.

About this research paper

What this paper is about

The acoustic stapedius reflex, which normally occurs at a hearing level of about 85 dB, can be detected at lower levels by means of sensitization. The technique is to apply reflex-eliciting tone and the facilitating tone stimulation. The high-frequency acoustic stapedius reflex can then be detected in this procedure under low-frequency facilitating. When hearing is normal, significant difference can be demonstrated between conventional and facilitated reflex threshold. There is a great amount of reflex threshold improvement with sensitization. Sensorineural hearing loss allowed small or no reflex threshold change with sensitization.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The acoustic stapedius reflex, which normally occurs at a hearing level of about 85 dB, can be detected at lower levels by means of sensitization. The technique is to apply reflex-eliciting tone and the facilitating tone stimulation. The high-frequency acoustic stapedius reflex can then be detected in this procedure under low-frequency facilitating. When hearing is normal, significant difference can be demonstrated between conventional and facilitated reflex threshold. There is a great amount of reflex threshold improvement with sensitization. Sensorineural hearing loss allowed small or no reflex threshold change with sensitization.

Key concepts: Acoustic reflex, Sensitization, Reflex, Audiology, Medicine, Sensorineural hearing loss, Tone (literature), Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
[The sensitization of acoustic stapedius reflex]. — Research Paper | ScholarLens