A robust large area x-ray imaging system based on 100 μ m thick Gas Electron Multiplier
F. D. Amaro, Jamil A. Mir, X. Carvalho, Carlos D. R. Azevedo, J.M.F. dos Santos, H. Natal da Luz
Abstract
Open-access reader
F. D. Amaro, Jamil A. Mir, X. Carvalho, Carlos D. R. Azevedo, J.M.F. dos Santos, H. Natal da Luz
Abstract
Open-access reader
We have developed an imaging detector based on a non-standard GEM, made from a 100 μ m thick kapton foil (2-fold thicker than standard GEM's). The 100 micron thick GEM is produced using the same wet etching technique as the standard GEM and is less prone to the damage caused by discharges, creating a robust detector that can safely operate at high gain. In this work we present the results obtained with a cascaded gaseous electron multiplier composed by two 100 micron thick GEM and a 10 × 10 cm 2 bi-dimensional readout electrode with resistive charge division. We have recorded energy resolution of 21% and charge gains above 10 4 when the detector was irradiated with 5.9 keV X-rays emitted by a 55 Fe radioactive source. We also present 10 × 10 cm 2 images acquired with the detector when irradiated with X-rays. The minimum position resolution recorded was 1.7 mm.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have developed an imaging detector based on a non-standard GEM, made from a 100 μ m thick kapton foil (2-fold thicker than standard GEM's). The 100 micron thick GEM is produced using the same wet etching technique as the standard GEM and is less prone to the damage caused by discharges, creating a robust detector that can safely operate at high gain. In this work we present the results obtained with a cascaded gaseous electron multiplier composed by two 100 micron thick GEM and a 10 × 10 cm 2 bi-dimensional readout electrode with resistive charge division. We have recorded energy resolution of 21% and charge gains above 10 4 when the detector was irradiated with 5.9 keV X-rays emitted by a 55 Fe radioactive source. We also present 10 × 10 cm 2 images acquired with the detector when irradiated with X-rays. The minimum position resolution recorded was 1.7 mm.
Key concepts: Gas electron multiplier, Kapton, Detector, Materials science, FOIL method, Outgassing, Etching (microfabrication), X-ray