2008PubMedRequires access

[Asymmetry of voltage concentration boundary layers effect in double-membrane diffusive cell].

Hanna Werner, Andrzej Ślęzak

Open publisher page 0 citations

Abstract

The aim of this work was to investigate the asymmetry of voltage concentration boundary layers effect in double-membrane diffusive cell, in which the membranes were fixed in horizontal planes. The research material consisted of flat, symmetrical and porous membrane of regenerated cellulose applied in the coil hemodialyzer and aqueous sodium chloride solutions. The studing of membrane electric voltages psi(o) and psi(s) were carried out in the series of two isothermal stages. In the first stage was established the psi(o)(t) characteristic in the conditions in which membranes M1 i M(r) were fixed vertically. In the second stage the psi(s)(t) characteristic was established in the situation in which M1 and M(r) membranes were fixed horizontally. In all stages the monitoring of membrane electrical voltages was carried out until the stationary state was achieved. The obtained results shows, that Psi(s) = psi(s)-psi(o) is the non-linear function of concentrations (C(ms)/C(o)) of the solutions being in the ranges both central (C(ms)) and external (C(o)) in a double-membrane diffusive cell. It has been stated that this cell has the properties of asymmetry the voltage effect of the concentration boundary layers. The measure of these properties is an adequate asymmetry coefficient. The value of this effect depends on the concentration of the solutions and the configuration of double-membrane diffusive cell.

About this research paper

What this paper is about

The aim of this work was to investigate the asymmetry of voltage concentration boundary layers effect in double-membrane diffusive cell, in which the membranes were fixed in horizontal planes. The research material consisted of flat, symmetrical and porous membrane of regenerated cellulose applied in the coil hemodialyzer and aqueous sodium chloride solutions. The studing of membrane electric voltages psi(o) and psi(s) were carried out in the series of two isothermal stages. In the first stage was established the psi(o)(t) characteristic in the conditions in which membranes M1 i M(r) were fixed vertically. In the second stage the psi(s)(t) characteristic was established in the situation in which M1 and M(r) membranes were fixed horizontally. In all stages the monitoring of membrane electrical voltages was carried out until the stationary state was achieved. The obtained results shows, that Psi(s) = psi(s)-psi(o) is the non-linear function of concentrations (C(ms)/C(o)) of the solutions being in the ranges both central (C(ms)) and external (C(o)) in a double-membrane diffusive cell. It has been stated that this cell has the properties of asymmetry the voltage effect of the concentration boundary layers. The measure of these properties is an adequate asymmetry coefficient. The value of this effect depends on the concentration of the solutions and the configuration of double-membrane diffusive cell.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this work was to investigate the asymmetry of voltage concentration boundary layers effect in double-membrane diffusive cell, in which the membranes were fixed in horizontal planes. The research material consisted of flat, symmetrical and porous membrane of regenerated cellulose applied in the coil hemodialyzer and aqueous sodium chloride solutions. The studing of membrane electric voltages psi(o) and psi(s) were carried out in the series of two isothermal stages. In the first stage was established the psi(o)(t) characteristic in the conditions in which membranes M1 i M(r) were fixed vertically. In the second stage the psi(s)(t) characteristic was established in the situation in which M1 and M(r) membranes were fixed horizontally. In all stages the monitoring of membrane electrical voltages was carried out until the stationary state was achieved. The obtained results shows, that Psi(s) = psi(s)-psi(o) is the non-linear function of concentrations (C(ms)/C(o)) of the solutions being in the ranges both central (C(ms)) and external (C(o)) in a double-membrane diffusive cell. It has been stated that this cell has the properties of asymmetry the voltage effect of the concentration boundary layers. The measure of these properties is an adequate asymmetry coefficient. The value of this effect depends on the concentration of the solutions and the configuration of double-membrane diffusive cell.

Key concepts: Membrane, Asymmetry, Voltage, Analytical Chemistry (journal), Aqueous solution, Materials science, Chemistry, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
[Asymmetry of voltage concentration boundary layers effect in double-membrane diffusive cell]. — Research Paper | ScholarLens