1992PubMedRequires access

Microplate coagulation assays.

Pratt Cw, Dougald M. Monroe

Open publisher page 32 citations

Abstract

This report describes the development of microplate-based blood coagulation assays. The assays require a kinetic microplate reader to follow changes in absorbance at 405 nm caused by the coagulating plasma. Procedures for performing prothrombin time and activated partial thromboplastin time tests are described with intra- and inter-assay variability of a few percentage points. The prothrombin time of normal plasma was 64.5 +/- 3.6 s, and the activated partial thromboplastin time was 69.8 +/- 3.2 s. Clotting times were prolonged when normal plasma was mixed with plasmas deficient in particular coagulation factors, as expected. These assays take advantage of the microplate format (small sample size and multiple simultaneous assays) and can be customized for specific purposes, such as quantifying purified factor IX or assessing protein C activity in plasma.

About this research paper

What this paper is about

This report describes the development of microplate-based blood coagulation assays. The assays require a kinetic microplate reader to follow changes in absorbance at 405 nm caused by the coagulating plasma. Procedures for performing prothrombin time and activated partial thromboplastin time tests are described with intra- and inter-assay variability of a few percentage points. The prothrombin time of normal plasma was 64.5 +/- 3.6 s, and the activated partial thromboplastin time was 69.8 +/- 3.2 s. Clotting times were prolonged when normal plasma was mixed with plasmas deficient in particular coagulation factors, as expected. These assays take advantage of the microplate format (small sample size and multiple simultaneous assays) and can be customized for specific purposes, such as quantifying purified factor IX or assessing protein C activity in plasma.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This report describes the development of microplate-based blood coagulation assays. The assays require a kinetic microplate reader to follow changes in absorbance at 405 nm caused by the coagulating plasma. Procedures for performing prothrombin time and activated partial thromboplastin time tests are described with intra- and inter-assay variability of a few percentage points. The prothrombin time of normal plasma was 64.5 +/- 3.6 s, and the activated partial thromboplastin time was 69.8 +/- 3.2 s. Clotting times were prolonged when normal plasma was mixed with plasmas deficient in particular coagulation factors, as expected. These assays take advantage of the microplate format (small sample size and multiple simultaneous assays) and can be customized for specific purposes, such as quantifying purified factor IX or assessing protein C activity in plasma.

Key concepts: Partial thromboplastin time, Prothrombin time, Thromboplastin, Coagulation, Thrombin generation, Chemistry, Chromatography, Clotting time

Related papers

Back to paper searchBrowse research topicsOriginal source
Microplate coagulation assays. — Research Paper | ScholarLens