1978PubMedRequires access

The relationship between suture number and quality of anastomoses in microvascular procedures.

Robertson Jh, Robertson Jt

Open publisher page 20 citations

Abstract

Microvascular end-to-side arterial anastomoses of vessels 1 to 2 mm in diameter were performed in 30 Sprague-Dawley rats. The animals studied differed in only one aspect, variance of suture number to complete the anastomosis. Angiographic and gross pathological evaluation of each animal demonstrated a direct correlation between quality of patency and number of sutures used to complete the anastomoses. A significant observation was made regarding unrecognized pathology in angiographically patent anastomosis.

About this research paper

What this paper is about

Microvascular end-to-side arterial anastomoses of vessels 1 to 2 mm in diameter were performed in 30 Sprague-Dawley rats. The animals studied differed in only one aspect, variance of suture number to complete the anastomosis. Angiographic and gross pathological evaluation of each animal demonstrated a direct correlation between quality of patency and number of sutures used to complete the anastomoses. A significant observation was made regarding unrecognized pathology in angiographically patent anastomosis.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microvascular end-to-side arterial anastomoses of vessels 1 to 2 mm in diameter were performed in 30 Sprague-Dawley rats. The animals studied differed in only one aspect, variance of suture number to complete the anastomosis. Angiographic and gross pathological evaluation of each animal demonstrated a direct correlation between quality of patency and number of sutures used to complete the anastomoses. A significant observation was made regarding unrecognized pathology in angiographically patent anastomosis.

Key concepts: Anastomosis, Medicine, Fibrous joint, Pathological, Anatomy, Surgical anastomosis, Surgery, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
The relationship between suture number and quality of anastomoses in microvascular procedures. — Research Paper | ScholarLens