1984PubMedRequires access

[Ventilation scintigraphy with 127Xenon gas--efficient use for emergency diagnosis of pulmonary embolism].

Jan Müller‐Brand, R Fridrich

Open publisher page 0 citations

Abstract

In a retrospective study all lung scans performed in 1982 were compared to those during 1983. In 1982, ventilation scans using 133Xe were performed first, followed by 6-view perfusion scans using 99mTc-MAA. In 251 patients, 149 (59%) had normal perfusion scans and the ventilation study was thus superfluous. In 95 patients (24%) the ventilation/perfusion defects matched. Only 43 patients (17%) had evidence of pulmonary embolism. In 1983, perfusion scans were performed first, and only patients with abnormality on the perfusion scan had a ventilation study using 127Xe. Of the 359 perfusion scans performed, 240 (67%) ruled out pulmonary embolism. Of the remaining 119 (33%), a ventilation study was performed immediately after the perfusion scan in the position showing a perfusion defect. A finding consistent with pulmonary embolism was observed in 58 patients (16%). In conclusion, the use of 127Xe in clinical practice represents a financial, technical and diagnostic advantage, as well as a reduction in radiation dose to patients and personnel.

About this research paper

What this paper is about

In a retrospective study all lung scans performed in 1982 were compared to those during 1983. In 1982, ventilation scans using 133Xe were performed first, followed by 6-view perfusion scans using 99mTc-MAA. In 251 patients, 149 (59%) had normal perfusion scans and the ventilation study was thus superfluous. In 95 patients (24%) the ventilation/perfusion defects matched. Only 43 patients (17%) had evidence of pulmonary embolism. In 1983, perfusion scans were performed first, and only patients with abnormality on the perfusion scan had a ventilation study using 127Xe. Of the 359 perfusion scans performed, 240 (67%) ruled out pulmonary embolism. Of the remaining 119 (33%), a ventilation study was performed immediately after the perfusion scan in the position showing a perfusion defect. A finding consistent with pulmonary embolism was observed in 58 patients (16%). In conclusion, the use of 127Xe in clinical practice represents a financial, technical and diagnostic advantage, as well as a reduction in radiation dose to patients and personnel.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In a retrospective study all lung scans performed in 1982 were compared to those during 1983. In 1982, ventilation scans using 133Xe were performed first, followed by 6-view perfusion scans using 99mTc-MAA. In 251 patients, 149 (59%) had normal perfusion scans and the ventilation study was thus superfluous. In 95 patients (24%) the ventilation/perfusion defects matched. Only 43 patients (17%) had evidence of pulmonary embolism. In 1983, perfusion scans were performed first, and only patients with abnormality on the perfusion scan had a ventilation study using 127Xe. Of the 359 perfusion scans performed, 240 (67%) ruled out pulmonary embolism. Of the remaining 119 (33%), a ventilation study was performed immediately after the perfusion scan in the position showing a perfusion defect. A finding consistent with pulmonary embolism was observed in 58 patients (16%). In conclusion, the use of 127Xe in clinical practice represents a financial, technical and diagnostic advantage, as well as a reduction in radiation dose to patients and personnel.

Key concepts: Medicine, Perfusion, Pulmonary embolism, Scintigraphy, Ventilation (architecture), Ventilation perfusion mismatch, Radiology, Embolism

Related papers

Back to paper searchBrowse research topicsOriginal source
[Ventilation scintigraphy with 127Xenon gas--efficient use for emergency diagnosis of pulmonary embolism]. — Research Paper | ScholarLens