2003PubMedRequires access

[Accuracy and precision of X-ray radiosurgery treatment for tumors in eyeball].

Yunyan Wang, Likuan Hu, Shuying Li, Bao Xiu-feng

Open publisher page 0 citations

Abstract

BACKGROUND & OBJECTIVE: Localization error in X-ray radiosurgery for tumors in eyeball was common due to the rotation of eyeball. The accuracy and precision of X-ray radiosurgery was studied by fixing the eyeball with micro-vacuo-certo-contacting ophthalmophanto (MVCCOP) to reduce the error in this article. METHODS: CT localization accuracy of X-ray radiosurgery system was measured using special markers in skull phantom. The eyeballs were fixed using MVCCOP, which was designed by the authors, and then the eyeball fixation accuracy and target localization accuracy were measured by comparing the CT localization coordinates and verification coordinates of corresponding points. RESULTS: The mean error of CT localization of BRW head-ring was 0.65 mm and maximum error was 1.09 mm. The mean error of fixation of eyeball using MVCCOP was 0.84 mm and maximal error was 1.17 mm. The accuracy of tumor localization in eyeball was 0.87 mm averagely and 1.19 mm maximally. The mean error of SRS200 was 0.22 mm and maximum error was 0.32 mm. The total error was 1.40 mm and 95 percentile confidence error was 2.12 mm. CONCLUSION: The accuracy and precision of X-ray radiosurgery using MVCCOP has come up to the standard of quality control of stereotactic radiosurgery. This localization method can reduce the localization errors in radiosurgery caused by the rotation of eyeball.

About this research paper

What this paper is about

BACKGROUND & OBJECTIVE: Localization error in X-ray radiosurgery for tumors in eyeball was common due to the rotation of eyeball. The accuracy and precision of X-ray radiosurgery was studied by fixing the eyeball with micro-vacuo-certo-contacting ophthalmophanto (MVCCOP) to reduce the error in this article. METHODS: CT localization accuracy of X-ray radiosurgery system was measured using special markers in skull phantom. The eyeballs were fixed using MVCCOP, which was designed by the authors, and then the eyeball fixation accuracy and target localization accuracy were measured by comparing the CT localization coordinates and verification coordinates of corresponding points. RESULTS: The mean error of CT localization of BRW head-ring was 0.65 mm and maximum error was 1.09 mm. The mean error of fixation of eyeball using MVCCOP was 0.84 mm and maximal error was 1.17 mm. The accuracy of tumor localization in eyeball was 0.87 mm averagely and 1.19 mm maximally. The mean error of SRS200 was 0.22 mm and maximum error was 0.32 mm. The total error was 1.40 mm and 95 percentile confidence error was 2.12 mm. CONCLUSION: The accuracy and precision of X-ray radiosurgery using MVCCOP has come up to the standard of quality control of stereotactic radiosurgery. This localization method can reduce the localization errors in radiosurgery caused by the rotation of eyeball.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND & OBJECTIVE: Localization error in X-ray radiosurgery for tumors in eyeball was common due to the rotation of eyeball. The accuracy and precision of X-ray radiosurgery was studied by fixing the eyeball with micro-vacuo-certo-contacting ophthalmophanto (MVCCOP) to reduce the error in this article. METHODS: CT localization accuracy of X-ray radiosurgery system was measured using special markers in skull phantom. The eyeballs were fixed using MVCCOP, which was designed by the authors, and then the eyeball fixation accuracy and target localization accuracy were measured by comparing the CT localization coordinates and verification coordinates of corresponding points. RESULTS: The mean error of CT localization of BRW head-ring was 0.65 mm and maximum error was 1.09 mm. The mean error of fixation of eyeball using MVCCOP was 0.84 mm and maximal error was 1.17 mm. The accuracy of tumor localization in eyeball was 0.87 mm averagely and 1.19 mm maximally. The mean error of SRS200 was 0.22 mm and maximum error was 0.32 mm. The total error was 1.40 mm and 95 percentile confidence error was 2.12 mm. CONCLUSION: The accuracy and precision of X-ray radiosurgery using MVCCOP has come up to the standard of quality control of stereotactic radiosurgery. This localization method can reduce the localization errors in radiosurgery caused by the rotation of eyeball.

Key concepts: Radiosurgery, Imaging phantom, Nuclear medicine, Accuracy and precision, Fixation (population genetics), Error analysis, Medicine, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
[Accuracy and precision of X-ray radiosurgery treatment for tumors in eyeball]. — Research Paper | ScholarLens