2014•PubMedRequires access

[Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography].

Guoquan Cao, Xiaojun Zhou, Huazhi Xu, Kehua Pan, Weijian Chen, Rui Li

Open publisher page 1 citations

Abstract

OBJECTIVE: To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner. METHODS: A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, occipital lobe and cerebellum. The image quality of CTA was evaluated by two experienced radiologists using double-blind method. The results were analyzed by statistics. RESULTS: Dose length product (DLP) in B group decreased 19.23% versus A group (3 419.40 vs 4 233.50 mGy·cm) .Every relative perfusion value of both sides from both groups were not statistically significant (P > 0.05) .Every relative perfusion parameter from individual territory in both groups showed no significant differences (P > 0.05) . The quality of CTA images between groups A and B were not statistically significant (P > 0.05) . CONCLUSION: On the premise that the accuracy of perfusion parameters and the quality of CTA images, the optimized scan protocol in whole-brain vessel one-stop examination can obviously reduce radiation dose and it has important clinical significance.

About this research paper

What this paper is about

OBJECTIVE: To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner. METHODS: A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, occipital lobe and cerebellum. The image quality of CTA was evaluated by two experienced radiologists using double-blind method. The results were analyzed by statistics. RESULTS: Dose length product (DLP) in B group decreased 19.23% versus A group (3 419.40 vs 4 233.50 mGy·cm) .Every relative perfusion value of both sides from both groups were not statistically significant (P > 0.05) .Every relative perfusion parameter from individual territory in both groups showed no significant differences (P > 0.05) . The quality of CTA images between groups A and B were not statistically significant (P > 0.05) . CONCLUSION: On the premise that the accuracy of perfusion parameters and the quality of CTA images, the optimized scan protocol in whole-brain vessel one-stop examination can obviously reduce radiation dose and it has important clinical significance.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner. METHODS: A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, occipital lobe and cerebellum. The image quality of CTA was evaluated by two experienced radiologists using double-blind method. The results were analyzed by statistics. RESULTS: Dose length product (DLP) in B group decreased 19.23% versus A group (3 419.40 vs 4 233.50 mGy·cm) .Every relative perfusion value of both sides from both groups were not statistically significant (P > 0.05) .Every relative perfusion parameter from individual territory in both groups showed no significant differences (P > 0.05) . The quality of CTA images between groups A and B were not statistically significant (P > 0.05) . CONCLUSION: On the premise that the accuracy of perfusion parameters and the quality of CTA images, the optimized scan protocol in whole-brain vessel one-stop examination can obviously reduce radiation dose and it has important clinical significance.

Key concepts: Nuclear medicine, Multislice, Medicine, Perfusion scanning, Computed tomographic, Tomography, Perfusion, Scanner

Related papers

Back to paper searchBrowse research topicsOriginal source
[Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography]. — Research Paper | ScholarLens