1998•Unpublished venueOpen access

Infrared pyrometer for temperature measurement of objects, emissivity of which depends on wavelength and time

Zbigniew Bielecki, Krzysztof Chrzanowski, Robert Matyszkiel, T. Piqtkowski, Marek Szulim

Open full text 1 citations

Abstract

The multiband MBP 98A pyrometer developed for non-contact temperature measurement of objects with unknown and wavelength-dependent emissivity has been presented in this paper.The pyrometer was designed using single thermoelectrically cooled PbS detector of spectral band of 1-2.5 Ilm and 8 narrow-band optical filters.It enables temperature measurement of objects at temperature within a range of 500°C-1200°C and a speed of 75 Hz.It can be used for controlling various industrial-technological processes as well as in research works for testing of classic singleband pyrometers in temperature measurement of objects whose emissivity depends on the wavelength and time.

Open-access reader

About this research paper

What this paper is about

The multiband MBP 98A pyrometer developed for non-contact temperature measurement of objects with unknown and wavelength-dependent emissivity has been presented in this paper.The pyrometer was designed using single thermoelectrically cooled PbS detector of spectral band of 1-2.5 Ilm and 8 narrow-band optical filters.It enables temperature measurement of objects at temperature within a range of 500°C-1200°C and a speed of 75 Hz.It can be used for controlling various industrial-technological processes as well as in research works for testing of classic singleband pyrometers in temperature measurement of objects whose emissivity depends on the wavelength and time.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The multiband MBP 98A pyrometer developed for non-contact temperature measurement of objects with unknown and wavelength-dependent emissivity has been presented in this paper.The pyrometer was designed using single thermoelectrically cooled PbS detector of spectral band of 1-2.5 Ilm and 8 narrow-band optical filters.It enables temperature measurement of objects at temperature within a range of 500°C-1200°C and a speed of 75 Hz.It can be used for controlling various industrial-technological processes as well as in research works for testing of classic singleband pyrometers in temperature measurement of objects whose emissivity depends on the wavelength and time.

Key concepts: Pyrometer, Emissivity, Wavelength, Temperature measurement, Infrared, Materials science, Optics, Radiometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Infrared pyrometer for temperature measurement of objects, emissivity of which depends on wavelength and time — Research Paper | ScholarLens