1973•鐵と鋼 : 日本鐡鋼協會々誌Open access

Comparative Study of Radiation Pyrometer and Blackbody

Toshio Shiraiwa, Yoichi TAMAMURA

Open full text 1 citations

Abstract

The characteristics of four types of radiation pyrometers in which Si cell, Phototube (Sl), thermopile, and PbS cell are used respectively, have been studied. Influences of emissivity variation, water film, steam, and scale on pyrometer readings are measured. A rotary furnace is used as a model that treats moving hot steel sheets.As the standard of radiation pyrometers, a blackbody furnace and its effective emissivity has been investigated.Results obtained are as follows.1) The effects of emissivity variation, water film, steam, and scale on are smaller for the radiation pyrometers using shorter wave lengths (

Open-access reader

About this research paper

What this paper is about

The characteristics of four types of radiation pyrometers in which Si cell, Phototube (Sl), thermopile, and PbS cell are used respectively, have been studied. Influences of emissivity variation, water film, steam, and scale on pyrometer readings are measured. A rotary furnace is used as a model that treats moving hot steel sheets.As the standard of radiation pyrometers, a blackbody furnace and its effective emissivity has been investigated.Results obtained are as follows.1) The effects of emissivity variation, water film, steam, and scale on are smaller for the radiation pyrometers using shorter wave lengths (

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The characteristics of four types of radiation pyrometers in which Si cell, Phototube (Sl), thermopile, and PbS cell are used respectively, have been studied. Influences of emissivity variation, water film, steam, and scale on pyrometer readings are measured. A rotary furnace is used as a model that treats moving hot steel sheets.As the standard of radiation pyrometers, a blackbody furnace and its effective emissivity has been investigated.Results obtained are as follows.1) The effects of emissivity variation, water film, steam, and scale on are smaller for the radiation pyrometers using shorter wave lengths (

Key concepts: Pyrometer, Emissivity, Black-body radiation, Radiation, Thermal radiation, Optics, Materials science, Thermopile