1998PubMedRequires access

[Comparison of anterior rhinomanometry and impulse oscillometry in nasal provocation with histamine].

Winfried Johannes Randerath, Smith Hj, Donna C. Knarr, K H Rühle

Open publisher page 4 citations

Abstract

UNLABELLED: Anterior rhinomanometry (aR) is the standard method for measurement of nasal resistance, but it has some drawbacks because it requires full co-operation of the patient and the results are disturbed by forced ventilation due to stenosis. The patient must generate flow by active ventilation. Resistance results from the flow/pressure ratio. Forced oscillation technique (IOS) does not affect spontaneous breathing. Flow/pressure ratio is generated externally by a loudspeaker. IOS measures not only resistance but also reactance. Whereas former methods used only a single frequency IOS is capable of applying and analysing frequencies between 0 and 100 Hz. The range from 5 to 35 Hz is useful for diagnostic issues. We compared IOS with aR in nasal provocation tests with histamine and checked the sensitivity of resistance (R) and reactance (X) at different frequencies. METHOD: 20 patients (13 m, 7 f) underwent nasal challenge test using increasing doses of histamine (max. 3.2 mg). Resistance (aR, IOS) and reactance (IOS) were measured parallel. To compare the two methods, we calculated the dose of histamine which is required to double nasal resistance. RESULTS: 1. IOS demonstrates the increase of R at all frequencies. 2. The highest increase of R is measured at a frequency of 5 Hz (5 Hz: NaCl 0.41 +/- 0.25; Hist. 1.26 +/- 0.57; 35 Hz: NaCl 0.36 +/- 0.172; Hist. 0.60 +/- 0.1 kPa/l/s, p < 0.001). 3. The critical dose is significantly lower in IOS than in aR (2.29 +/- 2.59 vs. 1.06 +/- 1.16 mg/ml, p < 0.02). 4. Basal values of R do not differ significantly between aR and IOS (0.37 +/- 0.12 vs. 0.41 +/- 0.25 kPa/l/s, p < 0.001). CONCLUSIONS: We conclude from our results that IOS is at least equivalent to aR in measuring nasal resistance. R at 5 Hz is the most important parameter in IOS. IOS is less dependent on the cooperation of the patient. In case of stenosis it does not require forced ventilation to achieve the required flow-pressure ratio.

About this research paper

What this paper is about

UNLABELLED: Anterior rhinomanometry (aR) is the standard method for measurement of nasal resistance, but it has some drawbacks because it requires full co-operation of the patient and the results are disturbed by forced ventilation due to stenosis. The patient must generate flow by active ventilation. Resistance results from the flow/pressure ratio. Forced oscillation technique (IOS) does not affect spontaneous breathing. Flow/pressure ratio is generated externally by a loudspeaker. IOS measures not only resistance but also reactance. Whereas former methods used only a single frequency IOS is capable of applying and analysing frequencies between 0 and 100 Hz. The range from 5 to 35 Hz is useful for diagnostic issues. We compared IOS with aR in nasal provocation tests with histamine and checked the sensitivity of resistance (R) and reactance (X) at different frequencies. METHOD: 20 patients (13 m, 7 f) underwent nasal challenge test using increasing doses of histamine (max. 3.2 mg). Resistance (aR, IOS) and reactance (IOS) were measured parallel. To compare the two methods, we calculated the dose of histamine which is required to double nasal resistance. RESULTS: 1. IOS demonstrates the increase of R at all frequencies. 2. The highest increase of R is measured at a frequency of 5 Hz (5 Hz: NaCl 0.41 +/- 0.25; Hist. 1.26 +/- 0.57; 35 Hz: NaCl 0.36 +/- 0.172; Hist. 0.60 +/- 0.1 kPa/l/s, p < 0.001). 3. The critical dose is significantly lower in IOS than in aR (2.29 +/- 2.59 vs. 1.06 +/- 1.16 mg/ml, p < 0.02). 4. Basal values of R do not differ significantly between aR and IOS (0.37 +/- 0.12 vs. 0.41 +/- 0.25 kPa/l/s, p < 0.001). CONCLUSIONS: We conclude from our results that IOS is at least equivalent to aR in measuring nasal resistance. R at 5 Hz is the most important parameter in IOS. IOS is less dependent on the cooperation of the patient. In case of stenosis it does not require forced ventilation to achieve the required flow-pressure ratio.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: Anterior rhinomanometry (aR) is the standard method for measurement of nasal resistance, but it has some drawbacks because it requires full co-operation of the patient and the results are disturbed by forced ventilation due to stenosis. The patient must generate flow by active ventilation. Resistance results from the flow/pressure ratio. Forced oscillation technique (IOS) does not affect spontaneous breathing. Flow/pressure ratio is generated externally by a loudspeaker. IOS measures not only resistance but also reactance. Whereas former methods used only a single frequency IOS is capable of applying and analysing frequencies between 0 and 100 Hz. The range from 5 to 35 Hz is useful for diagnostic issues. We compared IOS with aR in nasal provocation tests with histamine and checked the sensitivity of resistance (R) and reactance (X) at different frequencies. METHOD: 20 patients (13 m, 7 f) underwent nasal challenge test using increasing doses of histamine (max. 3.2 mg). Resistance (aR, IOS) and reactance (IOS) were measured parallel. To compare the two methods, we calculated the dose of histamine which is required to double nasal resistance. RESULTS: 1. IOS demonstrates the increase of R at all frequencies. 2. The highest increase of R is measured at a frequency of 5 Hz (5 Hz: NaCl 0.41 +/- 0.25; Hist. 1.26 +/- 0.57; 35 Hz: NaCl 0.36 +/- 0.172; Hist. 0.60 +/- 0.1 kPa/l/s, p < 0.001). 3. The critical dose is significantly lower in IOS than in aR (2.29 +/- 2.59 vs. 1.06 +/- 1.16 mg/ml, p < 0.02). 4. Basal values of R do not differ significantly between aR and IOS (0.37 +/- 0.12 vs. 0.41 +/- 0.25 kPa/l/s, p < 0.001). CONCLUSIONS: We conclude from our results that IOS is at least equivalent to aR in measuring nasal resistance. R at 5 Hz is the most important parameter in IOS. IOS is less dependent on the cooperation of the patient. In case of stenosis it does not require forced ventilation to achieve the required flow-pressure ratio.

Key concepts: Rhinomanometry, Provocation test, Reactance, Histamine, Medicine, Anesthesia, Work of breathing, Airway resistance

Related papers

Back to paper searchBrowse research topicsOriginal source
[Comparison of anterior rhinomanometry and impulse oscillometry in nasal provocation with histamine]. — Research Paper | ScholarLens