Determination of zinc pyrithione in shampoos by HPLC and HPLC-MS/MS.
Yu-Xiang Gu, Wang Qing-he, Ze-Lin Zhou, Qing Lv, Mai Cheng-hua
Abstract
Yu-Xiang Gu, Wang Qing-he, Ze-Lin Zhou, Qing Lv, Mai Cheng-hua
Abstract
Methods have been developed for the determination of zinc pyrithione (ZPT) in shampoos using high-performance liquid chromatography (HPLC) and high-performance liquid chromatography-mass spectrometry/mass spectrometry (HPLC-MS/MS). Samples were washed by water first to remove surfactant and water-soluble impurities, then ultrasonic-extracted by acetonitrile-methanol for 30 min, and finally analyzed by MG C18 column (250 mm x 4.6 mm, 5 μm) or RP-18e (100 mm x 3 mm, 2 μm) plus APCI-MS/MS. Limits of detection were determined as 0.015% (HPLC) and 0.003% (HPLC-MS/MS), with a limit of quantization of 0.05% and 0.01%, respectively. The recoveries were 85.8-104% (HPLC) and 87.6-107% (HPLC-MS/MS). A good linear relationship was obtained from 3.20 μg·ml(-1) to 200 μg·ml(-1) (HPLC) and 1.00 μg·ml(-1) to 200 μg·ml(-1) (HPLC-MS/MS). The proposed methods have been successfully applied to the analysis of ZPT in many shampoos. The established two methods were rapid and reproducible with low interference.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Methods have been developed for the determination of zinc pyrithione (ZPT) in shampoos using high-performance liquid chromatography (HPLC) and high-performance liquid chromatography-mass spectrometry/mass spectrometry (HPLC-MS/MS). Samples were washed by water first to remove surfactant and water-soluble impurities, then ultrasonic-extracted by acetonitrile-methanol for 30 min, and finally analyzed by MG C18 column (250 mm x 4.6 mm, 5 μm) or RP-18e (100 mm x 3 mm, 2 μm) plus APCI-MS/MS. Limits of detection were determined as 0.015% (HPLC) and 0.003% (HPLC-MS/MS), with a limit of quantization of 0.05% and 0.01%, respectively. The recoveries were 85.8-104% (HPLC) and 87.6-107% (HPLC-MS/MS). A good linear relationship was obtained from 3.20 μg·ml(-1) to 200 μg·ml(-1) (HPLC) and 1.00 μg·ml(-1) to 200 μg·ml(-1) (HPLC-MS/MS). The proposed methods have been successfully applied to the analysis of ZPT in many shampoos. The established two methods were rapid and reproducible with low interference.
Key concepts: Chromatography, High-performance liquid chromatography, Chemistry, Mass spectrometry, Detection limit