2000PubMedRequires access

[Effects of infusion methods of propofol on quality of sedation and ease of sedation control during gynecological laparotomy under spinal anesthesia].

Edward D. Matsumoto, Kentaro Yamasaki, Ken Nakata, A Hazama, Takashi Kita, Takeo Mammoto, Noriko Kambara, Taishi Sakai, Y. Kishi

Open publisher page 4 citations

Abstract

Twenty patients were prospectively and randomly studied to investigate effects of infusion methods of propofol on quality of sedation and ease of sedation control during gynecological laparotomy under spinal anesthesia. After establishment of spinal anesthesia, patients were randomly assigned to one of the following two groups, i.e. conventional continuous infusion group (Cont group) and target-controlled infusion group (TCI group). In the Cont group, propofol was started at a rate of 6 mg.kg-1.hr-1 until response to command disappeared. In the TCI group, the initial target concentration of propofol was set at 1.2 micrograms.ml-1 until response to command disappeared. Thereafter infusion rate or target concentration was adjusted to maintain Mackenzie's score at 3 or 4. Predicted concentration of propofol was 1.2 +/- 0.01 micrograms.ml-1 at induction of sedation and 1.2 +/- 0.11 micrograms.ml-1 during stable sedation in the TCI group. Satisfaction VAS, anxiety VAS, discomfort VAS, sedation score and times of changing infusion condition were similar in both groups. Total dose of propofol was significantly less in the TCI group. In conclusion, quality of sedation and ease of control of sedation were comparable in both groups and continuous infusion method is simple.

About this research paper

What this paper is about

Twenty patients were prospectively and randomly studied to investigate effects of infusion methods of propofol on quality of sedation and ease of sedation control during gynecological laparotomy under spinal anesthesia. After establishment of spinal anesthesia, patients were randomly assigned to one of the following two groups, i.e. conventional continuous infusion group (Cont group) and target-controlled infusion group (TCI group). In the Cont group, propofol was started at a rate of 6 mg.kg-1.hr-1 until response to command disappeared. In the TCI group, the initial target concentration of propofol was set at 1.2 micrograms.ml-1 until response to command disappeared. Thereafter infusion rate or target concentration was adjusted to maintain Mackenzie's score at 3 or 4. Predicted concentration of propofol was 1.2 +/- 0.01 micrograms.ml-1 at induction of sedation and 1.2 +/- 0.11 micrograms.ml-1 during stable sedation in the TCI group. Satisfaction VAS, anxiety VAS, discomfort VAS, sedation score and times of changing infusion condition were similar in both groups. Total dose of propofol was significantly less in the TCI group. In conclusion, quality of sedation and ease of control of sedation were comparable in both groups and continuous infusion method is simple.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Twenty patients were prospectively and randomly studied to investigate effects of infusion methods of propofol on quality of sedation and ease of sedation control during gynecological laparotomy under spinal anesthesia. After establishment of spinal anesthesia, patients were randomly assigned to one of the following two groups, i.e. conventional continuous infusion group (Cont group) and target-controlled infusion group (TCI group). In the Cont group, propofol was started at a rate of 6 mg.kg-1.hr-1 until response to command disappeared. In the TCI group, the initial target concentration of propofol was set at 1.2 micrograms.ml-1 until response to command disappeared. Thereafter infusion rate or target concentration was adjusted to maintain Mackenzie's score at 3 or 4. Predicted concentration of propofol was 1.2 +/- 0.01 micrograms.ml-1 at induction of sedation and 1.2 +/- 0.11 micrograms.ml-1 during stable sedation in the TCI group. Satisfaction VAS, anxiety VAS, discomfort VAS, sedation score and times of changing infusion condition were similar in both groups. Total dose of propofol was significantly less in the TCI group. In conclusion, quality of sedation and ease of control of sedation were comparable in both groups and continuous infusion method is simple.

Key concepts: Propofol, Sedation, Anesthesia, Medicine, Target controlled infusion, Laparotomy, Surgery, Remifentanil

Related papers

Back to paper searchBrowse research topicsOriginal source
[Effects of infusion methods of propofol on quality of sedation and ease of sedation control during gynecological laparotomy under spinal anesthesia]. — Research Paper | ScholarLens