2004PubMedRequires access

[Accuracy of intraocular pressure measurement using NCT after LASIK].

Yubing Chen, Gang-Ping Zhao, Meirong Pan, Qihua Zheng

Open publisher page 2 citations

Abstract

PURPOSE: To study the accuracy of the intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) with noncontact tonometer (NCT). METHODS: One hundred and eighty cases (256 eyes) myopias that had undergone LASIK were studied. IOP, corneal thickness and corneal curvature were measured before and after LASIK. The correlations were analyzed. RESULTS: The decrease of Iop using NCT was significantly obvious after LASIK (P < 0.001). One year after LASIK mean IOP drop was 6.54 +/- 2.1 mmHg. The reduction of IOP may be related to the decrease in corneal thickness and corneal curvature (P < 0.01). Regression equation for IOP drop (mmHg) = 0.355 + 0.0342X1 + 0.365X2 [X1 = decrease in corneal curvature (D), X2 = ablation depth (microm)] CONCLUSIONS: The IOP readings after LASIK were lower than the real IOP values. IOP readings after LASIK were influenced by corneal thickness and refraction degree.

About this research paper

What this paper is about

PURPOSE: To study the accuracy of the intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) with noncontact tonometer (NCT). METHODS: One hundred and eighty cases (256 eyes) myopias that had undergone LASIK were studied. IOP, corneal thickness and corneal curvature were measured before and after LASIK. The correlations were analyzed. RESULTS: The decrease of Iop using NCT was significantly obvious after LASIK (P < 0.001). One year after LASIK mean IOP drop was 6.54 +/- 2.1 mmHg. The reduction of IOP may be related to the decrease in corneal thickness and corneal curvature (P < 0.01). Regression equation for IOP drop (mmHg) = 0.355 + 0.0342X1 + 0.365X2 [X1 = decrease in corneal curvature (D), X2 = ablation depth (microm)] CONCLUSIONS: The IOP readings after LASIK were lower than the real IOP values. IOP readings after LASIK were influenced by corneal thickness and refraction degree.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To study the accuracy of the intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) with noncontact tonometer (NCT). METHODS: One hundred and eighty cases (256 eyes) myopias that had undergone LASIK were studied. IOP, corneal thickness and corneal curvature were measured before and after LASIK. The correlations were analyzed. RESULTS: The decrease of Iop using NCT was significantly obvious after LASIK (P < 0.001). One year after LASIK mean IOP drop was 6.54 +/- 2.1 mmHg. The reduction of IOP may be related to the decrease in corneal thickness and corneal curvature (P < 0.01). Regression equation for IOP drop (mmHg) = 0.355 + 0.0342X1 + 0.365X2 [X1 = decrease in corneal curvature (D), X2 = ablation depth (microm)] CONCLUSIONS: The IOP readings after LASIK were lower than the real IOP values. IOP readings after LASIK were influenced by corneal thickness and refraction degree.

Key concepts: LASIK, Keratomileusis, Intraocular pressure, Ophthalmology, Medicine, Ablation, Cornea, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Accuracy of intraocular pressure measurement using NCT after LASIK]. — Research Paper | ScholarLens