2002PubMedRequires access

Arterial response during cutting balloon angioplasty: a volumetric intravascular ultrasound study.

Chih-Kuan Liao, Heidi N. Bonneau, Paul G. Yock, Peter J. Fitzgerald

Open publisher page 5 citations

Abstract

BACKGROUND AND PURPOSE: Previous studies have demonstrated that the mechanism of acute lumen enlargement after balloon angioplasty is a combination of vessel expansion and plaque redistribution, but not plaque compression. The purpose of this study was to clarify, from a three-dimensional aspect, the vascular response to cutting balloon angioplasty. METHODS: Serial intravascular ultrasound (IVUS) studies, including pre- and post-intervention, were performed in 36 native coronary lesions treated with the cutting balloon device. External elastic membrane (EEM), lumen, and plaque + media cross-sectional area were measured at 16-frame intervals (30 frames = 1 mm) over a lesion length of 16 mm with the center on the smallest pre-intervention lumen area. Volumetric calculations were based on Simpson's rule. RESULTS: EEM volume (261.16 +/- 89.59 vs. 279.59 +/- 85.92 mm3; p < 0.01) and lumen volume (106.48 +/- 37.83 v.s. 133.72 +/- 36.57 mm3; p < 0.01) significantly increased after cutting balloon angioplasty. Furthermore, the plaque + media volume throughout the lesion changed significantly after cutting balloon angioplasty (154.68 +/- 63.36 vs. 145.87 +/- 59.20 mm3; p < 0.01). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.75; p < 0.01), but poorly with the change in plaque + media volume (r = 0.08; p = 0.64). Less longitudinal plaque redistribution was also observed throughout the vessel after angioplasty. CONCLUSION: The results of this study indicate that the predominant mechanism of lumen enlargement from cutting balloon angioplasty is vessel expansion, although total plaque mass reduction and longitudinal plaque redistribution do occur.

About this research paper

What this paper is about

BACKGROUND AND PURPOSE: Previous studies have demonstrated that the mechanism of acute lumen enlargement after balloon angioplasty is a combination of vessel expansion and plaque redistribution, but not plaque compression. The purpose of this study was to clarify, from a three-dimensional aspect, the vascular response to cutting balloon angioplasty. METHODS: Serial intravascular ultrasound (IVUS) studies, including pre- and post-intervention, were performed in 36 native coronary lesions treated with the cutting balloon device. External elastic membrane (EEM), lumen, and plaque + media cross-sectional area were measured at 16-frame intervals (30 frames = 1 mm) over a lesion length of 16 mm with the center on the smallest pre-intervention lumen area. Volumetric calculations were based on Simpson's rule. RESULTS: EEM volume (261.16 +/- 89.59 vs. 279.59 +/- 85.92 mm3; p < 0.01) and lumen volume (106.48 +/- 37.83 v.s. 133.72 +/- 36.57 mm3; p < 0.01) significantly increased after cutting balloon angioplasty. Furthermore, the plaque + media volume throughout the lesion changed significantly after cutting balloon angioplasty (154.68 +/- 63.36 vs. 145.87 +/- 59.20 mm3; p < 0.01). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.75; p < 0.01), but poorly with the change in plaque + media volume (r = 0.08; p = 0.64). Less longitudinal plaque redistribution was also observed throughout the vessel after angioplasty. CONCLUSION: The results of this study indicate that the predominant mechanism of lumen enlargement from cutting balloon angioplasty is vessel expansion, although total plaque mass reduction and longitudinal plaque redistribution do occur.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND PURPOSE: Previous studies have demonstrated that the mechanism of acute lumen enlargement after balloon angioplasty is a combination of vessel expansion and plaque redistribution, but not plaque compression. The purpose of this study was to clarify, from a three-dimensional aspect, the vascular response to cutting balloon angioplasty. METHODS: Serial intravascular ultrasound (IVUS) studies, including pre- and post-intervention, were performed in 36 native coronary lesions treated with the cutting balloon device. External elastic membrane (EEM), lumen, and plaque + media cross-sectional area were measured at 16-frame intervals (30 frames = 1 mm) over a lesion length of 16 mm with the center on the smallest pre-intervention lumen area. Volumetric calculations were based on Simpson's rule. RESULTS: EEM volume (261.16 +/- 89.59 vs. 279.59 +/- 85.92 mm3; p < 0.01) and lumen volume (106.48 +/- 37.83 v.s. 133.72 +/- 36.57 mm3; p < 0.01) significantly increased after cutting balloon angioplasty. Furthermore, the plaque + media volume throughout the lesion changed significantly after cutting balloon angioplasty (154.68 +/- 63.36 vs. 145.87 +/- 59.20 mm3; p < 0.01). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.75; p < 0.01), but poorly with the change in plaque + media volume (r = 0.08; p = 0.64). Less longitudinal plaque redistribution was also observed throughout the vessel after angioplasty. CONCLUSION: The results of this study indicate that the predominant mechanism of lumen enlargement from cutting balloon angioplasty is vessel expansion, although total plaque mass reduction and longitudinal plaque redistribution do occur.

Key concepts: Intravascular ultrasound, Medicine, Balloon, Angioplasty, Lumen (anatomy), Cutting balloon, Lesion, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Arterial response during cutting balloon angioplasty: a volumetric intravascular ultrasound study. — Research Paper | ScholarLens