2002PubMedRequires access

Cutting balloon angioplasty for treatment of coronary in-stent restenosis: immediate results and 6-month outcomes.

Shao‐Liang Chen, Duan Baoxiang, Zhizhong Liu, Xiang Wu, Fuxiang Wei, Xueli Qian, Fei Ye, Wuwang Fang, Zuo‐Ying Hu, Isreal Tamari, Huaiqing Chen

Open publisher page 2 citations

Abstract

OBJECTIVE: To determine the mid-term effects of cutting balloon angioplasty (CBA) on in-stent restenosis. METHODS: A total of 69 patients with in-stent restenosis were divided into 2 groups randomly: cutting balloon angioplasty and plain old balloon angioplasty. The mechanisms of restenosis and dilation results were determined by quantitative coronary angiography and intravascular ultrasound. Follow-up was performed. RESULTS: The procedural success rate was 100% without death and acute closure. One patient experienced dissection at the distal end of the stent and needed another stent. The mean follow-up period was 6.7 +/- 2.3 months. The final re-restenosis rate was 15% and 18% at 3 months and 6 months respectively, markedly lower than after plain old balloon angioplasty (38% and 43%). Acute gain by intravascular ultrasound (IVUS) was 1.72 +/- 0.52 mm after cutting balloon angioplasty, higher than 1.15 +/- 0.54 mm after plain old balloon angioplasty. The lumen diameter late loss in the cutting balloon group was 0.26 +/- 0.05 mm and 0.38 +/- 0.06 mm at 3 months and 6 months respectively, significantly lower than for those in conventional balloon group (0.78 +/- 0.19 mm and 0.89 +/- 0.16 mm, respectively, P < 0.001). As shown by IVUS, the main mechanism of cutting balloon angioplasty was marked reduction of plaque area without significant increase of vessel area (less vessel trauma). CONCLUSION: Cutting balloon angioplasty is feasible and effective for the treatment of in-stent restenosis with less vessel trauma.

About this research paper

What this paper is about

OBJECTIVE: To determine the mid-term effects of cutting balloon angioplasty (CBA) on in-stent restenosis. METHODS: A total of 69 patients with in-stent restenosis were divided into 2 groups randomly: cutting balloon angioplasty and plain old balloon angioplasty. The mechanisms of restenosis and dilation results were determined by quantitative coronary angiography and intravascular ultrasound. Follow-up was performed. RESULTS: The procedural success rate was 100% without death and acute closure. One patient experienced dissection at the distal end of the stent and needed another stent. The mean follow-up period was 6.7 +/- 2.3 months. The final re-restenosis rate was 15% and 18% at 3 months and 6 months respectively, markedly lower than after plain old balloon angioplasty (38% and 43%). Acute gain by intravascular ultrasound (IVUS) was 1.72 +/- 0.52 mm after cutting balloon angioplasty, higher than 1.15 +/- 0.54 mm after plain old balloon angioplasty. The lumen diameter late loss in the cutting balloon group was 0.26 +/- 0.05 mm and 0.38 +/- 0.06 mm at 3 months and 6 months respectively, significantly lower than for those in conventional balloon group (0.78 +/- 0.19 mm and 0.89 +/- 0.16 mm, respectively, P < 0.001). As shown by IVUS, the main mechanism of cutting balloon angioplasty was marked reduction of plaque area without significant increase of vessel area (less vessel trauma). CONCLUSION: Cutting balloon angioplasty is feasible and effective for the treatment of in-stent restenosis with less vessel trauma.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine the mid-term effects of cutting balloon angioplasty (CBA) on in-stent restenosis. METHODS: A total of 69 patients with in-stent restenosis were divided into 2 groups randomly: cutting balloon angioplasty and plain old balloon angioplasty. The mechanisms of restenosis and dilation results were determined by quantitative coronary angiography and intravascular ultrasound. Follow-up was performed. RESULTS: The procedural success rate was 100% without death and acute closure. One patient experienced dissection at the distal end of the stent and needed another stent. The mean follow-up period was 6.7 +/- 2.3 months. The final re-restenosis rate was 15% and 18% at 3 months and 6 months respectively, markedly lower than after plain old balloon angioplasty (38% and 43%). Acute gain by intravascular ultrasound (IVUS) was 1.72 +/- 0.52 mm after cutting balloon angioplasty, higher than 1.15 +/- 0.54 mm after plain old balloon angioplasty. The lumen diameter late loss in the cutting balloon group was 0.26 +/- 0.05 mm and 0.38 +/- 0.06 mm at 3 months and 6 months respectively, significantly lower than for those in conventional balloon group (0.78 +/- 0.19 mm and 0.89 +/- 0.16 mm, respectively, P < 0.001). As shown by IVUS, the main mechanism of cutting balloon angioplasty was marked reduction of plaque area without significant increase of vessel area (less vessel trauma). CONCLUSION: Cutting balloon angioplasty is feasible and effective for the treatment of in-stent restenosis with less vessel trauma.

Key concepts: Angioplasty, Restenosis, Medicine, Balloon, Cutting balloon, Intravascular ultrasound, Stent, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Cutting balloon angioplasty for treatment of coronary in-stent restenosis: immediate results and 6-month outcomes. — Research Paper | ScholarLens