[Clinical study of imposed work of breathing caused by the breathing apparatus].
Qiu H, Shumei Ma, Liu D
Abstract
Qiu H, Shumei Ma, Liu D
Abstract
OBJECTIVE: The imposed work of breathing caused by the breathing apparatus (endotracheal tube, breathing circuit tubing, and ventilator's valves) may increase patient's work of breathing. To evaluate the imposed work may be useful to determine weaning. METHODS: Work of breathing was observed by Bicore CP-100 breathing monitor at different levels pressure support (PS), T piece and after extubation, and the PS level to compensate imposed work of breathing was computed. RESULTS: When PS level decreased, patient's work of breathing increased significantly. At PS O kPa, the patient's work of breathing increased 57%, which was caused by imposed work of apparatus. Because of the resistance of endotracheal tube, the patient's work of breathing increased 41% at T piece. The PS level that compensated for the imposed work was 0.7 kPa. CONCLUSIONS: When PS level was too low or T piece was applied, the imposed work of breathing caused by apparatus could markedly increase patient's work of breathing.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: The imposed work of breathing caused by the breathing apparatus (endotracheal tube, breathing circuit tubing, and ventilator's valves) may increase patient's work of breathing. To evaluate the imposed work may be useful to determine weaning. METHODS: Work of breathing was observed by Bicore CP-100 breathing monitor at different levels pressure support (PS), T piece and after extubation, and the PS level to compensate imposed work of breathing was computed. RESULTS: When PS level decreased, patient's work of breathing increased significantly. At PS O kPa, the patient's work of breathing increased 57%, which was caused by imposed work of apparatus. Because of the resistance of endotracheal tube, the patient's work of breathing increased 41% at T piece. The PS level that compensated for the imposed work was 0.7 kPa. CONCLUSIONS: When PS level was too low or T piece was applied, the imposed work of breathing caused by apparatus could markedly increase patient's work of breathing.
Key concepts: Work of breathing, Breathing, Endotracheal tube, Work (physics), Medicine, Tube (container), Ventilation (architecture), Anesthesia