2007PubMedRequires access

[Implications of serum matrix metalloproteinase-8 elevation in patients with acute coronary syndrome].

Hua Qiang, Zhao-Xia Zhou, Aiqun Ma, Hua Cheng, Ping Zhou

Open publisher page 4 citations

Abstract

OBJECTIVE: To study the clinical significance of serum matrix metalloproteinase-8 (MMP-8) concentration variation in patients with acute coronary syndrome (ACS). METHODS: Enzyme-linked immunosorbent assay (ELISA) was employed to detect serum MMP-8 content in 80 ACS patients, including 43 with acute myocardial infarction (AMI), and 37 with unstable angina pectoris (UAP), as well as in 43 with stable angina pectoris (SAP) cases and 37 control subjects. The risk factors for atherosclerosis pertaining to age, sex, hypertension, body mass index, smoking, family history, diabetes, hyperlipidemia, etc. were evaluated statistically in each case. RESULTS: Serum MMP-8 concentration was significantly higher in ACS group than in SAP and control groups (Plt;0.01). In ASC group, serum MMP-8 was much higher in AMI patients than in those with UAP (Plt;0.01), but similar between UAP and SAP groups (P>0.05). Logistic regression analysis identified serum MMP-8 concentration as the possible indicator of ACS (B=4.493, P=0.000), and particularly AMI (B=9.961, P=0.000). Linear correlation and linear regression analysis revealed that only neutrophils were associated with serum MMP-8 concentration variation (r=0.274, P=0.001). CONCLUSIONS: Serum MMP-8 concentration is closely associated with ACS, particularly AMI, and may serve as an indicator for predicting ACS and AMI. Neutrophils may be connected with the variation of serum MMP-8 concentration, but not as the major factor.

About this research paper

What this paper is about

OBJECTIVE: To study the clinical significance of serum matrix metalloproteinase-8 (MMP-8) concentration variation in patients with acute coronary syndrome (ACS). METHODS: Enzyme-linked immunosorbent assay (ELISA) was employed to detect serum MMP-8 content in 80 ACS patients, including 43 with acute myocardial infarction (AMI), and 37 with unstable angina pectoris (UAP), as well as in 43 with stable angina pectoris (SAP) cases and 37 control subjects. The risk factors for atherosclerosis pertaining to age, sex, hypertension, body mass index, smoking, family history, diabetes, hyperlipidemia, etc. were evaluated statistically in each case. RESULTS: Serum MMP-8 concentration was significantly higher in ACS group than in SAP and control groups (Plt;0.01). In ASC group, serum MMP-8 was much higher in AMI patients than in those with UAP (Plt;0.01), but similar between UAP and SAP groups (P>0.05). Logistic regression analysis identified serum MMP-8 concentration as the possible indicator of ACS (B=4.493, P=0.000), and particularly AMI (B=9.961, P=0.000). Linear correlation and linear regression analysis revealed that only neutrophils were associated with serum MMP-8 concentration variation (r=0.274, P=0.001). CONCLUSIONS: Serum MMP-8 concentration is closely associated with ACS, particularly AMI, and may serve as an indicator for predicting ACS and AMI. Neutrophils may be connected with the variation of serum MMP-8 concentration, but not as the major factor.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To study the clinical significance of serum matrix metalloproteinase-8 (MMP-8) concentration variation in patients with acute coronary syndrome (ACS). METHODS: Enzyme-linked immunosorbent assay (ELISA) was employed to detect serum MMP-8 content in 80 ACS patients, including 43 with acute myocardial infarction (AMI), and 37 with unstable angina pectoris (UAP), as well as in 43 with stable angina pectoris (SAP) cases and 37 control subjects. The risk factors for atherosclerosis pertaining to age, sex, hypertension, body mass index, smoking, family history, diabetes, hyperlipidemia, etc. were evaluated statistically in each case. RESULTS: Serum MMP-8 concentration was significantly higher in ACS group than in SAP and control groups (Plt;0.01). In ASC group, serum MMP-8 was much higher in AMI patients than in those with UAP (Plt;0.01), but similar between UAP and SAP groups (P>0.05). Logistic regression analysis identified serum MMP-8 concentration as the possible indicator of ACS (B=4.493, P=0.000), and particularly AMI (B=9.961, P=0.000). Linear correlation and linear regression analysis revealed that only neutrophils were associated with serum MMP-8 concentration variation (r=0.274, P=0.001). CONCLUSIONS: Serum MMP-8 concentration is closely associated with ACS, particularly AMI, and may serve as an indicator for predicting ACS and AMI. Neutrophils may be connected with the variation of serum MMP-8 concentration, but not as the major factor.

Key concepts: Medicine, Unstable angina, Acute coronary syndrome, Internal medicine, Myocardial infarction, Diabetes mellitus, Logistic regression, Hyperlipidemia

Related papers

Back to paper searchBrowse research topicsOriginal source
[Implications of serum matrix metalloproteinase-8 elevation in patients with acute coronary syndrome]. — Research Paper | ScholarLens