Accuracy and Reliability of the i-STAT Point-of-Care Device for the Determination of Haemoglobin Concentration before and after Major Blood Loss
W. L. Ng, Timothy G. Short, Kerry Gunn, G. S. Fuge, Barry Slon
Abstract
Open-access reader
W. L. Ng, Timothy G. Short, Kerry Gunn, G. S. Fuge, Barry Slon
Abstract
Open-access reader
We investigated the accuracy of i-STAT(®) (Abbott Point of Care Inc., Princeton, NJ, USA) haemoglobin (Hb) measurement in surgical patients with an estimated blood loss of ≥25% of total blood volume. Blood tests for i-STAT(®) Hb, laboratory Hb (Sysmex XE-2100(™), Sysmex Corporation, Kobe, Japan) and total plasma proteins were obtained at the start of surgery (T=0) and when an estimated 25% total blood volume loss had occurred (T=1). Thirty-one patients were recruited. The coefficient of variation of the paired i-STAT(®) Hb estimates was 2.8% and 2.9% at T=0 and T=1, respectively. The mean difference between i-STAT(®) and laboratory Hb was -7.6 g/l (standard deviation 6.5) at T=0 and -5.1 g/l (standard deviation 12) at T=1. The mean total plasma protein difference (total plasma protein T=0 minus T=1) was 13.6 g/l (95% confidence interval 10.2 to 17.0). There was poor correlation between total plasma protein and bias in i-STAT(®) measurements. The i-STAT(®) Hb had an acceptable coefficient of variation, but the Hb levels were lower than those estimated by the laboratory. The standard deviation of i-STAT(®) Hb was greater after ≥25% estimated total blood volume loss. Clinicians should not use the i-STAT(®) Hb in isolation for clinical decision-making when considering blood transfusion in a situation of 25% or greater blood loss.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We investigated the accuracy of i-STAT(®) (Abbott Point of Care Inc., Princeton, NJ, USA) haemoglobin (Hb) measurement in surgical patients with an estimated blood loss of ≥25% of total blood volume. Blood tests for i-STAT(®) Hb, laboratory Hb (Sysmex XE-2100(™), Sysmex Corporation, Kobe, Japan) and total plasma proteins were obtained at the start of surgery (T=0) and when an estimated 25% total blood volume loss had occurred (T=1). Thirty-one patients were recruited. The coefficient of variation of the paired i-STAT(®) Hb estimates was 2.8% and 2.9% at T=0 and T=1, respectively. The mean difference between i-STAT(®) and laboratory Hb was -7.6 g/l (standard deviation 6.5) at T=0 and -5.1 g/l (standard deviation 12) at T=1. The mean total plasma protein difference (total plasma protein T=0 minus T=1) was 13.6 g/l (95% confidence interval 10.2 to 17.0). There was poor correlation between total plasma protein and bias in i-STAT(®) measurements. The i-STAT(®) Hb had an acceptable coefficient of variation, but the Hb levels were lower than those estimated by the laboratory. The standard deviation of i-STAT(®) Hb was greater after ≥25% estimated total blood volume loss. Clinicians should not use the i-STAT(®) Hb in isolation for clinical decision-making when considering blood transfusion in a situation of 25% or greater blood loss.
Key concepts: Medicine, Reliability (semiconductor), Point of care, stat, Blood loss, Point-of-care testing, Reliability engineering, Surgery