1992The Korean Journal of Nuclear MedicineRequires access

Exercise Radionuclide Ventriculography in Patients with Mitral Stenosis

Do-Yun Lee, Won‐Heum Shim, Han‐Soo Kim, Seung‐Jung Park, Seung-Yun Cho, Sungsoon Kim, Woong-Ku Lee, Myeong‐Jin Kim, Kyu-Ok Choe, Chang-Yun Park

Open publisher page 0 citations

Abstract

We performed exercise radionuclide ventriculography to evaluate left ventricular (LV) function in 35 patients with pure mitral stenosis (MS). There were 6 males and 29 females ranging from 21 to 63 years of age (mean years). We also studied 8 healthy men as control group (mean age years). Each patients was evaluated at rest and during maximal exercise on an isokinetic bicycle ergometer. Peak filling rate (PFR), peak ejection rate (PER), ejection fracion (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and cardiac output (CO) were determined by the radionuclide technique. The results were summarized as follows: 1) LV systolic dysfunction and reduced PFR were noted in patients with MS. 2) EDV as well as SV decreased with exercise in patients with MS. 3) No significant increase in EF during exercise compared to rest value was observed because it was caused by reduced EDV and SV during exercise in patients with MS. 4) CO increased with exercise was significantly lower than normal in patients with MS. 5) Patients with MS were divided into two groups according to whether SF increased more than 5% druing exercise compared to resting state or decreased. Significant difference were found between these two groups. Patients with a fall in EF with exercise were older, had larger left atrial size, and had lesser decreased in ESV during exercise.

About this research paper

What this paper is about

We performed exercise radionuclide ventriculography to evaluate left ventricular (LV) function in 35 patients with pure mitral stenosis (MS). There were 6 males and 29 females ranging from 21 to 63 years of age (mean years). We also studied 8 healthy men as control group (mean age years). Each patients was evaluated at rest and during maximal exercise on an isokinetic bicycle ergometer. Peak filling rate (PFR), peak ejection rate (PER), ejection fracion (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and cardiac output (CO) were determined by the radionuclide technique. The results were summarized as follows: 1) LV systolic dysfunction and reduced PFR were noted in patients with MS. 2) EDV as well as SV decreased with exercise in patients with MS. 3) No significant increase in EF during exercise compared to rest value was observed because it was caused by reduced EDV and SV during exercise in patients with MS. 4) CO increased with exercise was significantly lower than normal in patients with MS. 5) Patients with MS were divided into two groups according to whether SF increased more than 5% druing exercise compared to resting state or decreased. Significant difference were found between these two groups. Patients with a fall in EF with exercise were older, had larger left atrial size, and had lesser decreased in ESV during exercise.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We performed exercise radionuclide ventriculography to evaluate left ventricular (LV) function in 35 patients with pure mitral stenosis (MS). There were 6 males and 29 females ranging from 21 to 63 years of age (mean years). We also studied 8 healthy men as control group (mean age years). Each patients was evaluated at rest and during maximal exercise on an isokinetic bicycle ergometer. Peak filling rate (PFR), peak ejection rate (PER), ejection fracion (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and cardiac output (CO) were determined by the radionuclide technique. The results were summarized as follows: 1) LV systolic dysfunction and reduced PFR were noted in patients with MS. 2) EDV as well as SV decreased with exercise in patients with MS. 3) No significant increase in EF during exercise compared to rest value was observed because it was caused by reduced EDV and SV during exercise in patients with MS. 4) CO increased with exercise was significantly lower than normal in patients with MS. 5) Patients with MS were divided into two groups according to whether SF increased more than 5% druing exercise compared to resting state or decreased. Significant difference were found between these two groups. Patients with a fall in EF with exercise were older, had larger left atrial size, and had lesser decreased in ESV during exercise.

Key concepts: Radionuclide ventriculography, Cardiology, Medicine, Internal medicine, Stroke volume, Ejection fraction, Heart rate, Cardiac output

Related papers

Back to paper searchBrowse research topicsOriginal source
Exercise Radionuclide Ventriculography in Patients with Mitral Stenosis — Research Paper | ScholarLens