1991Journal of Nippon Medical SchoolOpen access

Radionuclide ventriculographic evaluation of exercised leftventricular performance in asymptomatic diabetic patients.

Yusuke Fujii, Fumio HARA

Open full text 1 citations

Abstract

Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30-70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4 +/- 9.8% (mean +/- SD) to 60.3 +/- 9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3 +/- 8.4 to 63.0 +/- 11.4 (p less than 0.05)]. Peak ejection rates were similar in both groups at rest [-2.62 +/- 0.64 (s-1) vs -2.66 +/- 0.52] and during dynamic exercise [-3.25 +/- 0.74 vs -3.23 +/- 0.90]. Time to end-systole were similar in both groups at rest [315 +/- 42 (ms) vs 309 +/- 42] and during dynamic exercise [258 +/- 37 vs 262 +/- 37]. The resting peak filling rates were similar in both groups [2.27 +/- 0.62 (s-1) vs 2.45 +/- 0.58], and the peak filling rates increased (p less than 0.001) during dynamic exercise in both groups [2.68 +/- 0.61 vs 3.28 +/- 0.74]. However, the percent changes of the peak filling rates were significantly lower in diabetic patients (p less than 0.001). In four of the diabetic patients, hypokinesis of the intraventricular septum was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Open-access reader

About this research paper

What this paper is about

Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30-70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4 +/- 9.8% (mean +/- SD) to 60.3 +/- 9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3 +/- 8.4 to 63.0 +/- 11.4 (p less than 0.05)]. Peak ejection rates were similar in both groups at rest [-2.62 +/- 0.64 (s-1) vs -2.66 +/- 0.52] and during dynamic exercise [-3.25 +/- 0.74 vs -3.23 +/- 0.90]. Time to end-systole were similar in both groups at rest [315 +/- 42 (ms) vs 309 +/- 42] and during dynamic exercise [258 +/- 37 vs 262 +/- 37]. The resting peak filling rates were similar in both groups [2.27 +/- 0.62 (s-1) vs 2.45 +/- 0.58], and the peak filling rates increased (p less than 0.001) during dynamic exercise in both groups [2.68 +/- 0.61 vs 3.28 +/- 0.74]. However, the percent changes of the peak filling rates were significantly lower in diabetic patients (p less than 0.001). In four of the diabetic patients, hypokinesis of the intraventricular septum was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30-70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4 +/- 9.8% (mean +/- SD) to 60.3 +/- 9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3 +/- 8.4 to 63.0 +/- 11.4 (p less than 0.05)]. Peak ejection rates were similar in both groups at rest [-2.62 +/- 0.64 (s-1) vs -2.66 +/- 0.52] and during dynamic exercise [-3.25 +/- 0.74 vs -3.23 +/- 0.90]. Time to end-systole were similar in both groups at rest [315 +/- 42 (ms) vs 309 +/- 42] and during dynamic exercise [258 +/- 37 vs 262 +/- 37]. The resting peak filling rates were similar in both groups [2.27 +/- 0.62 (s-1) vs 2.45 +/- 0.58], and the peak filling rates increased (p less than 0.001) during dynamic exercise in both groups [2.68 +/- 0.61 vs 3.28 +/- 0.74]. However, the percent changes of the peak filling rates were significantly lower in diabetic patients (p less than 0.001). In four of the diabetic patients, hypokinesis of the intraventricular septum was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Key concepts: Radionuclide ventriculography, Medicine, Supine position, Asymptomatic, Cardiology, Internal medicine, Ejection fraction, Diabetes mellitus

Related papers

Back to paper searchBrowse research topicsOriginal source
Radionuclide ventriculographic evaluation of exercised leftventricular performance in asymptomatic diabetic patients. — Research Paper | ScholarLens