The Effect of Phacoemulsification with Oscillation Device on the Cornea and Lens Opcatiy
So-Yeon Gil, Seungbum Kang, Seung‐Hee Lee, Sung-Kun Chung
Abstract
So-Yeon Gil, Seungbum Kang, Seung‐Hee Lee, Sung-Kun Chung
Abstract
Purpose: To access the effect of phacoemulsification, using Neosonix? (Alcon Laboratories, TX, USA), on the cornea and lens opacity. Methods: This study involved 42 eyes of 37 patients who underwent phacoemulsification using the Neosonix from December 2005 through March 2006. We measured the density and the thickness of lenses using a Scheimpflug camera and evaluated the correlation between the density and the phaco time. To evaluate the effects of Neosonix? on the corneal endothelium, we measured various corneal endothelial cell parameters, including corneal endothelial cell density, corneal thickness, and morphologic changes up to two months postoperatively. Results: The preoperative mean values of lens density for the anterior cortex, nucleus, and posterior cortex were 105.86±34.99 CCT, 82.17±35.14 CCT, and 77.88±52.98 CCT, respectively. The mean phacoemulsification time was 48.67±29.79 seconds and increased significantly, according to the increase of the densities of the lens nucleus and cortex (p0.05). Conclusions: The phacoemulsification time using oscillation device significantly increased as the density of the lens cortex and nucleus increased, and there was no statistically significant difference between the preoperative and postoperative values of corneal endothelial cell density.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Purpose: To access the effect of phacoemulsification, using Neosonix? (Alcon Laboratories, TX, USA), on the cornea and lens opacity. Methods: This study involved 42 eyes of 37 patients who underwent phacoemulsification using the Neosonix from December 2005 through March 2006. We measured the density and the thickness of lenses using a Scheimpflug camera and evaluated the correlation between the density and the phaco time. To evaluate the effects of Neosonix? on the corneal endothelium, we measured various corneal endothelial cell parameters, including corneal endothelial cell density, corneal thickness, and morphologic changes up to two months postoperatively. Results: The preoperative mean values of lens density for the anterior cortex, nucleus, and posterior cortex were 105.86±34.99 CCT, 82.17±35.14 CCT, and 77.88±52.98 CCT, respectively. The mean phacoemulsification time was 48.67±29.79 seconds and increased significantly, according to the increase of the densities of the lens nucleus and cortex (p0.05). Conclusions: The phacoemulsification time using oscillation device significantly increased as the density of the lens cortex and nucleus increased, and there was no statistically significant difference between the preoperative and postoperative values of corneal endothelial cell density.
Key concepts: Phacoemulsification, Scheimpflug principle, Ophthalmology, Medicine, Cornea, Corneal endothelium, Lens (geology), Cortex (anatomy)