2014Journal of environmental healthRequires access

Determination of trace lead in environmental water body by carbon nanotube solid phase extraction-flame atomic absorption spectrometry

Wang Nan

Open publisher page 0 citations

Abstract

Objective To establish a method for the determination of trace lead in environmental water body by carbon nanotube solid phase extraction-flame atomic absorption spectrometry. Methods Lead in environmental water samples was concentrated by carbon nanotube and the concentration was determined by flame atomic absorption spectrometry. The best optimum experimental conditions were as follows: pH 6.0 of water sample, 60 min extraction,1.0 mol/L nitrite acid as desorption solvent, 10 min desorption. Results The limit of detection was 1.4 μg/L, the average recovery rates were 100.3%-100.7% and RSD was 2.1%. Conclusion The method is applicable to the determination of trace lead in various environmental water body with good convenience,sensitivity and reliability.

About this research paper

What this paper is about

Objective To establish a method for the determination of trace lead in environmental water body by carbon nanotube solid phase extraction-flame atomic absorption spectrometry. Methods Lead in environmental water samples was concentrated by carbon nanotube and the concentration was determined by flame atomic absorption spectrometry. The best optimum experimental conditions were as follows: pH 6.0 of water sample, 60 min extraction,1.0 mol/L nitrite acid as desorption solvent, 10 min desorption. Results The limit of detection was 1.4 μg/L, the average recovery rates were 100.3%-100.7% and RSD was 2.1%. Conclusion The method is applicable to the determination of trace lead in various environmental water body with good convenience,sensitivity and reliability.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for the determination of trace lead in environmental water body by carbon nanotube solid phase extraction-flame atomic absorption spectrometry. Methods Lead in environmental water samples was concentrated by carbon nanotube and the concentration was determined by flame atomic absorption spectrometry. The best optimum experimental conditions were as follows: pH 6.0 of water sample, 60 min extraction,1.0 mol/L nitrite acid as desorption solvent, 10 min desorption. Results The limit of detection was 1.4 μg/L, the average recovery rates were 100.3%-100.7% and RSD was 2.1%. Conclusion The method is applicable to the determination of trace lead in various environmental water body with good convenience,sensitivity and reliability.

Key concepts: Detection limit, Desorption, Carbon nanotube, Chemistry, Extraction (chemistry), Atomic absorption spectroscopy, Solid phase extraction, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace lead in environmental water body by carbon nanotube solid phase extraction-flame atomic absorption spectrometry — Research Paper | ScholarLens