2013Northwest Pharmaceutical JournalRequires access

Determination of chromium in soft capsules shells of drug and health food by microwave digestion-furnace atom absorption spectrometry

Huang Anju

Open publisher page 0 citations

Abstract

Objective To establish a method of microwave digestion-furnace atom absorption spectrometry for the determination of chromium in soft capsule shells of drug and health food.Methods The determination conditions of microwave digestion-furnace atom absorbance spectrometry were optimized.The content of chromium was determined under the wavelength of 357.9nm,with the slit width 0.7nm.Results The calibration curve was linear in the range of 0-50μg·L-1(r=0.998 9),the limit of detection was 0.02mg·kg-1,and the limit of quantification was 0.08mg·kg-1.The average recoveries at three levels were 101.4%,100.8% and 99.7%,respectively,and the RSD were 1.9%,2.1%and 3.2%,respectively.Conclusion This method is simple,accurate,and suitable for the determination of chromium in soft capsule shells of drug and health food.

About this research paper

What this paper is about

Objective To establish a method of microwave digestion-furnace atom absorption spectrometry for the determination of chromium in soft capsule shells of drug and health food.Methods The determination conditions of microwave digestion-furnace atom absorbance spectrometry were optimized.The content of chromium was determined under the wavelength of 357.9nm,with the slit width 0.7nm.Results The calibration curve was linear in the range of 0-50μg·L-1(r=0.998 9),the limit of detection was 0.02mg·kg-1,and the limit of quantification was 0.08mg·kg-1.The average recoveries at three levels were 101.4%,100.8% and 99.7%,respectively,and the RSD were 1.9%,2.1%and 3.2%,respectively.Conclusion This method is simple,accurate,and suitable for the determination of chromium in soft capsule shells of drug and health food.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method of microwave digestion-furnace atom absorption spectrometry for the determination of chromium in soft capsule shells of drug and health food.Methods The determination conditions of microwave digestion-furnace atom absorbance spectrometry were optimized.The content of chromium was determined under the wavelength of 357.9nm,with the slit width 0.7nm.Results The calibration curve was linear in the range of 0-50μg·L-1(r=0.998 9),the limit of detection was 0.02mg·kg-1,and the limit of quantification was 0.08mg·kg-1.The average recoveries at three levels were 101.4%,100.8% and 99.7%,respectively,and the RSD were 1.9%,2.1%and 3.2%,respectively.Conclusion This method is simple,accurate,and suitable for the determination of chromium in soft capsule shells of drug and health food.

Key concepts: Chromium, Absorbance, Microwave digestion, Detection limit, Calibration curve, Chemistry, Microwave, Digestion (alchemy)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of chromium in soft capsules shells of drug and health food by microwave digestion-furnace atom absorption spectrometry — Research Paper | ScholarLens