Determination of trace mercury in hawthorn leaf by new cold mercury generation- atomic absorption spectrometry with microwave digestion
Keyan Wang
Abstract
Keyan Wang
Abstract
Objective To establish a method for determination of trace mercury in hawthorn leaf by new cold mercury generation- atomic absorption spectrometry with microwave digestion. Methods After pretreatment by microwave digestion system,trace mercury in several common Chinese herbal medicine were determined by cold mercury generation- atomic absorption spectrometry. Results When using the nitric acid + hydrofluoric acid peroxide reagent at the ratio of 8: 1 as acid digestion reagent in the digestion process,the samples will be completely digested Wide linear relationship was achieved in the range of 10μg / L ~ 50μg / L with relative coefficient of 0. 9999 and the detection limit was 0. 041μg / g with RSD of 2. 24% formercury at 30μg / L. With respect to the average recovery was 99. 2%,relative standard deviation was 2. 12%,RSD% accuracy is good. Conclusion The method determination of trace mercury in hawthorn leaves is safe environmental protection,simple and fast,accurate,sensitive and has a good application prospect.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a method for determination of trace mercury in hawthorn leaf by new cold mercury generation- atomic absorption spectrometry with microwave digestion. Methods After pretreatment by microwave digestion system,trace mercury in several common Chinese herbal medicine were determined by cold mercury generation- atomic absorption spectrometry. Results When using the nitric acid + hydrofluoric acid peroxide reagent at the ratio of 8: 1 as acid digestion reagent in the digestion process,the samples will be completely digested Wide linear relationship was achieved in the range of 10μg / L ~ 50μg / L with relative coefficient of 0. 9999 and the detection limit was 0. 041μg / g with RSD of 2. 24% formercury at 30μg / L. With respect to the average recovery was 99. 2%,relative standard deviation was 2. 12%,RSD% accuracy is good. Conclusion The method determination of trace mercury in hawthorn leaves is safe environmental protection,simple and fast,accurate,sensitive and has a good application prospect.
Key concepts: Mercury (programming language), Microwave digestion, Chemistry, Atomic absorption spectroscopy, Reagent, Nitric acid, Detection limit, Analytical Chemistry (journal)