Trace determination of mercury in rice using microwave digestion coupling with atomic fluorescence spectrometry
Wang Li
Abstract
Wang Li
Abstract
Objective:To establish a rapid,precise and sensitive method for the trace determination of mercury in rice by microwave digestion coupling with atomic fluorescence spectrometer approach.Methods:After a pretreatment with nitric acid/hydrogen peroxide microwave digestion system,we used atomic fluorescence spectrometer methodology to determine trace mercury in rice.Results:Under the optimized digestion and detection conditions: nitric acid/water/hydrogen peroxide ratio,4:4:2;KBH4 concentraton,0.3%(w/w);lamp current,20 mA;flow rate of carrying gas,300 ml/min;carrying flow,5% HCl,wide linear relationship was achieved in the range of 0.1~50.0 μg/L with relative coefficient of 0.9999 and the detection limit was estimated to be 0.0114 μg/L.We got satisfied recovery rates of spiked samples of 98.9% to 105.9% with RSD of four replicate experiments less than 6.6%.Conclusion:The present method is precise,rapid and sensitive enough for determination of trace mercury in rice.The detection results indicate that rice in Ningbo market is mostly safe.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish a rapid,precise and sensitive method for the trace determination of mercury in rice by microwave digestion coupling with atomic fluorescence spectrometer approach.Methods:After a pretreatment with nitric acid/hydrogen peroxide microwave digestion system,we used atomic fluorescence spectrometer methodology to determine trace mercury in rice.Results:Under the optimized digestion and detection conditions: nitric acid/water/hydrogen peroxide ratio,4:4:2;KBH4 concentraton,0.3%(w/w);lamp current,20 mA;flow rate of carrying gas,300 ml/min;carrying flow,5% HCl,wide linear relationship was achieved in the range of 0.1~50.0 μg/L with relative coefficient of 0.9999 and the detection limit was estimated to be 0.0114 μg/L.We got satisfied recovery rates of spiked samples of 98.9% to 105.9% with RSD of four replicate experiments less than 6.6%.Conclusion:The present method is precise,rapid and sensitive enough for determination of trace mercury in rice.The detection results indicate that rice in Ningbo market is mostly safe.
Key concepts: Mercury (programming language), Detection limit, Microwave digestion, Nitric acid, Chemistry, Hydrogen peroxide, Analytical Chemistry (journal), Linear range