[Determination of norfloxacin, an active dissociation product of silver norfloxacin, in guinea pig plasma and tissue by high performance liquid chromatography with column-switching].
Liu Ll, Ming Cheng, Gao S
Abstract
Liu Ll, Ming Cheng, Gao S
Abstract
A column switching HPLC method was established for the determination of norfloxacin, and active dissociation product of silver norfloxacin, in guinea pig plasma and tissues. The pre-treating column (50 mm x 5 mm ID) and analytical column (150 mm x 5 mm ID) were packed with mu-Bondapak C18, 37-50 microns and YWG-C18, 10 microns, respectively. A mixture of CH3OH-0.008 mol/L phosphate buffer-0.05 mol/L tetrabutylammoniun bromide (25:75:4) was used as the analytical mobile phase with a flow rate of 1 ml/min. The pre-treating mobile phase was 0.008 mol/L phosphate buffer with a flow rate of 3 ml/min. UV detection was made at 280 nm. The results were linear within a range of 2-128 micrograms/ml norfloxacin for plasma. The lowest detection limit was 0.25 microgram/ml for plasma. The mean recovery of the method was 102% with a relative standard deviation of less than 7%.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A column switching HPLC method was established for the determination of norfloxacin, and active dissociation product of silver norfloxacin, in guinea pig plasma and tissues. The pre-treating column (50 mm x 5 mm ID) and analytical column (150 mm x 5 mm ID) were packed with mu-Bondapak C18, 37-50 microns and YWG-C18, 10 microns, respectively. A mixture of CH3OH-0.008 mol/L phosphate buffer-0.05 mol/L tetrabutylammoniun bromide (25:75:4) was used as the analytical mobile phase with a flow rate of 1 ml/min. The pre-treating mobile phase was 0.008 mol/L phosphate buffer with a flow rate of 3 ml/min. UV detection was made at 280 nm. The results were linear within a range of 2-128 micrograms/ml norfloxacin for plasma. The lowest detection limit was 0.25 microgram/ml for plasma. The mean recovery of the method was 102% with a relative standard deviation of less than 7%.
Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Norfloxacin, Detection limit, Dissociation (chemistry), Volumetric flow rate, Plasma