2002Acta Scientiarum Naturalium Universitatis NeimongolRequires access

Study on the Colour Reaction of Titanium (IV) with 5′-Nitrosalicylfluorone and CTMAB and Its Application

Yu Yan

Open publisher page 0 citations

Abstract

A new photometric method has been developed for the determination of Ti with 5′ Nitrosalicylfluorone(5′ NSF). In the presence of cetyltrimethyl ammonium bromide (CTMAB),Ti (Ⅳ) reacts rapidly with 5′ NSF to form a ternary micelle complex in 0.012~0.020mol/L hydrochloric acid medium.The apparent molar absorptivity of the complex is 1.36×10 5L·mol -1 cm -1 at 599 nm ,and the composition ratio of Ti(Ⅳ): 5′ NSF is 1:4. Beer′s Law is obeyed for Titanium(Ⅳ) in the range of 0~8μg/25ml. The proposed method is sensitive and selective, which has been applied to determine the trace amounts of titanium in alloy steels with satisfactory results.

About this research paper

What this paper is about

A new photometric method has been developed for the determination of Ti with 5′ Nitrosalicylfluorone(5′ NSF). In the presence of cetyltrimethyl ammonium bromide (CTMAB),Ti (Ⅳ) reacts rapidly with 5′ NSF to form a ternary micelle complex in 0.012~0.020mol/L hydrochloric acid medium.The apparent molar absorptivity of the complex is 1.36×10 5L·mol -1 cm -1 at 599 nm ,and the composition ratio of Ti(Ⅳ): 5′ NSF is 1:4. Beer′s Law is obeyed for Titanium(Ⅳ) in the range of 0~8μg/25ml. The proposed method is sensitive and selective, which has been applied to determine the trace amounts of titanium in alloy steels with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new photometric method has been developed for the determination of Ti with 5′ Nitrosalicylfluorone(5′ NSF). In the presence of cetyltrimethyl ammonium bromide (CTMAB),Ti (Ⅳ) reacts rapidly with 5′ NSF to form a ternary micelle complex in 0.012~0.020mol/L hydrochloric acid medium.The apparent molar absorptivity of the complex is 1.36×10 5L·mol -1 cm -1 at 599 nm ,and the composition ratio of Ti(Ⅳ): 5′ NSF is 1:4. Beer′s Law is obeyed for Titanium(Ⅳ) in the range of 0~8μg/25ml. The proposed method is sensitive and selective, which has been applied to determine the trace amounts of titanium in alloy steels with satisfactory results.

Key concepts: Molar absorptivity, Titanium, Hydrochloric acid, Ammonium bromide, Chemistry, Ternary operation, Inorganic chemistry, Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Colour Reaction of Titanium (IV) with 5′-Nitrosalicylfluorone and CTMAB and Its Application — Research Paper | ScholarLens