Experimental research on internal relative humidity during dying shrinkage of concrete

Yong Yuan

Open publisher page 2 citations

Abstract

Internal relative humidity in concrete is a controlling factor of dying shrinkage. A new measuring system using embedded digital sensors has been developed that provides a convenient and easy way to accurately measuring the internal relative humidity of concrete from very early age. The internal relative humidity and drying shrinkage of non-standard specimen for C30 normal concrete and C60 high performance concrete are measured at drying shrinkage condition. A linear equation between drying shrinkage and internal relative humidity of concrete are established using regression theory.

About this research paper

What this paper is about

Internal relative humidity in concrete is a controlling factor of dying shrinkage. A new measuring system using embedded digital sensors has been developed that provides a convenient and easy way to accurately measuring the internal relative humidity of concrete from very early age. The internal relative humidity and drying shrinkage of non-standard specimen for C30 normal concrete and C60 high performance concrete are measured at drying shrinkage condition. A linear equation between drying shrinkage and internal relative humidity of concrete are established using regression theory.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Internal relative humidity in concrete is a controlling factor of dying shrinkage. A new measuring system using embedded digital sensors has been developed that provides a convenient and easy way to accurately measuring the internal relative humidity of concrete from very early age. The internal relative humidity and drying shrinkage of non-standard specimen for C30 normal concrete and C60 high performance concrete are measured at drying shrinkage condition. A linear equation between drying shrinkage and internal relative humidity of concrete are established using regression theory.

Key concepts: Shrinkage, Relative humidity, Humidity, Materials science, Composite material, Internal heating, Environmental science, Meteorology