2005•Metallurgical AnalysisRequires access

Determination of nitrogen oxide in air by sequential injection analysis with chemiluminescence detection

Shihua Fan

Open publisher page 0 citations

Abstract

Nitride reacts with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium,which is an unstable state in acid medium and subsequently was quenched into peroxynitrite in basic solution.Based on this,a sequential injection chemiluminescence method for the determination of trace amounts of nitrogen oxide in air was established.During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and cetyl trimethyl ammonium bromide(CTMAB). The product from the reaction between nitrogen dioxide and triethanolamine was used as an absorbing solution for NO_2 in the conversion of NO_2 to nitrite. The reaction coil(flow cell) and holding coil were combined as a new sampling means.The detection limit of NO_2 is 1×10~(-7) mol/L for 50 μL sample and the sampling frequency is 80 samples per hour.The linear range of the calibration curve is from 1×10~(-7) to 1×10~(-4) mol/L.The relative standard deviation for 1×10~(-5) mol/L NO_2 is 2.7% with the recovery of 85%-104%.

About this research paper

What this paper is about

Nitride reacts with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium,which is an unstable state in acid medium and subsequently was quenched into peroxynitrite in basic solution.Based on this,a sequential injection chemiluminescence method for the determination of trace amounts of nitrogen oxide in air was established.During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and cetyl trimethyl ammonium bromide(CTMAB). The product from the reaction between nitrogen dioxide and triethanolamine was used as an absorbing solution for NO_2 in the conversion of NO_2 to nitrite. The reaction coil(flow cell) and holding coil were combined as a new sampling means.The detection limit of NO_2 is 1×10~(-7) mol/L for 50 μL sample and the sampling frequency is 80 samples per hour.The linear range of the calibration curve is from 1×10~(-7) to 1×10~(-4) mol/L.The relative standard deviation for 1×10~(-5) mol/L NO_2 is 2.7% with the recovery of 85%-104%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Nitride reacts with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium,which is an unstable state in acid medium and subsequently was quenched into peroxynitrite in basic solution.Based on this,a sequential injection chemiluminescence method for the determination of trace amounts of nitrogen oxide in air was established.During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and cetyl trimethyl ammonium bromide(CTMAB). The product from the reaction between nitrogen dioxide and triethanolamine was used as an absorbing solution for NO_2 in the conversion of NO_2 to nitrite. The reaction coil(flow cell) and holding coil were combined as a new sampling means.The detection limit of NO_2 is 1×10~(-7) mol/L for 50 μL sample and the sampling frequency is 80 samples per hour.The linear range of the calibration curve is from 1×10~(-7) to 1×10~(-4) mol/L.The relative standard deviation for 1×10~(-5) mol/L NO_2 is 2.7% with the recovery of 85%-104%.

Key concepts: Chemiluminescence, Chemistry, Detection limit, Triethanolamine, Hydrogen peroxide, Nitrite, Sulfuric acid, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of nitrogen oxide in air by sequential injection analysis with chemiluminescence detection — Research Paper | ScholarLens