2005•PubMedRequires access

[Determination of nitrite in water samples by sequential injection analysis with chemiluminescence detection on chip flow cell].

Yang Wang, Shihua Fan

Open publisher page 0 citations

Abstract

A sequential injection chemiluminescence's system using a chip flow cell was described for the determination of trace amount of nitrite in water samples. Nitride reacted with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium, which was an unstable in acid medium and subsequently was quenched into peroxynitrite in basic solution. During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and ethyldimethylcetylammonium bromide. The reaction coil (flow cell) and holding coil was combined for tracking the emission signal. The experimental parameters including physical and chemical parameter were optimized. The interference of cations in water samples was eliminated by passing previously the sample solution through a cation-exchange column. The linear range of the calibration graph was obtained from 1 x 10(-6) to 1 x 10(-4) mol x L(-1) with a correlation coefficient of 0.9998. The detection limit at 95% confidence was 6.8 x 10(-7) mol x L(-1). The relative standard deviation at 1 x 10(-5) mol x L(-1) nitrite level was 2.7%, and the recovery of 90%-99% and the sampling frequency of 80 h(-1) were obtained.

About this research paper

What this paper is about

A sequential injection chemiluminescence's system using a chip flow cell was described for the determination of trace amount of nitrite in water samples. Nitride reacted with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium, which was an unstable in acid medium and subsequently was quenched into peroxynitrite in basic solution. During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and ethyldimethylcetylammonium bromide. The reaction coil (flow cell) and holding coil was combined for tracking the emission signal. The experimental parameters including physical and chemical parameter were optimized. The interference of cations in water samples was eliminated by passing previously the sample solution through a cation-exchange column. The linear range of the calibration graph was obtained from 1 x 10(-6) to 1 x 10(-4) mol x L(-1) with a correlation coefficient of 0.9998. The detection limit at 95% confidence was 6.8 x 10(-7) mol x L(-1). The relative standard deviation at 1 x 10(-5) mol x L(-1) nitrite level was 2.7%, and the recovery of 90%-99% and the sampling frequency of 80 h(-1) were obtained.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sequential injection chemiluminescence's system using a chip flow cell was described for the determination of trace amount of nitrite in water samples. Nitride reacted with hydrogen peroxide to form peroxynitrous acid in sulfuric acid medium, which was an unstable in acid medium and subsequently was quenched into peroxynitrite in basic solution. During the composition of peroxynitrite the chemiluminescence intensity was enhanced with the presence of uranin and ethyldimethylcetylammonium bromide. The reaction coil (flow cell) and holding coil was combined for tracking the emission signal. The experimental parameters including physical and chemical parameter were optimized. The interference of cations in water samples was eliminated by passing previously the sample solution through a cation-exchange column. The linear range of the calibration graph was obtained from 1 x 10(-6) to 1 x 10(-4) mol x L(-1) with a correlation coefficient of 0.9998. The detection limit at 95% confidence was 6.8 x 10(-7) mol x L(-1). The relative standard deviation at 1 x 10(-5) mol x L(-1) nitrite level was 2.7%, and the recovery of 90%-99% and the sampling frequency of 80 h(-1) were obtained.

Key concepts: Detection limit, Chemiluminescence, Chemistry, Nitrite, Analytical Chemistry (journal), Hydrogen peroxide, Sulfuric acid, Flow injection analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of nitrite in water samples by sequential injection analysis with chemiluminescence detection on chip flow cell]. — Research Paper | ScholarLens