Spectrophotometric Methods Based on Diazotion-coupling Reaction for the Determination of Aniline Concentration in Water
Zhao Mu-qiu
Abstract
Zhao Mu-qiu
Abstract
[Objective] The aim was to establish six spectrophotometric methods for determining aniline concentration in water based on diazotion-coupling reaction.[Method] Aniline coupled with N-(1-naphthyl)-ethylenediamine,α-naphthyl amine,α-naphthol,guaiacol,8-hydroxy-quinoline or chromotropic acid in sodium nitrite medium to form colored dye.[Result] The maximum absorption wavelength of resultant was 545、540、495、450、480 or 510nm,the linear range was 0-5.5,0-6.0,0-6.5,0-11.5,0-10.0 or 0-9.5mg/L,and the limit of detection was 0.009,0.011,0.014,0.032,0.025 or 0.022 mg/L,respectively.The rates of recovery were 95.1-105.3%,and RSDs were 1.96-4.80% respectively.Compared with gas chromatography,no significant difference presented using these 6 methods determining aniline concentration in waste water.[Conclusion] These six methods are simple and accurate and applicable to the determination of aniline concentration in water.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Objective] The aim was to establish six spectrophotometric methods for determining aniline concentration in water based on diazotion-coupling reaction.[Method] Aniline coupled with N-(1-naphthyl)-ethylenediamine,α-naphthyl amine,α-naphthol,guaiacol,8-hydroxy-quinoline or chromotropic acid in sodium nitrite medium to form colored dye.[Result] The maximum absorption wavelength of resultant was 545、540、495、450、480 or 510nm,the linear range was 0-5.5,0-6.0,0-6.5,0-11.5,0-10.0 or 0-9.5mg/L,and the limit of detection was 0.009,0.011,0.014,0.032,0.025 or 0.022 mg/L,respectively.The rates of recovery were 95.1-105.3%,and RSDs were 1.96-4.80% respectively.Compared with gas chromatography,no significant difference presented using these 6 methods determining aniline concentration in waste water.[Conclusion] These six methods are simple and accurate and applicable to the determination of aniline concentration in water.
Key concepts: Aniline, Chemistry, Sodium nitrite, Ethylenediamine, Nitrite, Detection limit, Quinoline, Amine gas treating