Determination of 33 weedicides and pesticides in foods by gas chromatography-mass spectrometry and selected ion monitoring
Lou Shu-qing
Abstract
Lou Shu-qing
Abstract
Objective:To establish a method for determination of 33 organophosphorus,pyrethroid,organochlorine,carbamate and weedicide pesticides in foods by gas chromatography-mass spectrometry(GC-MS) and selected ion monitoring(SIM).Methods:The pesticides were extracted with acetone and dichloromethane.The extract was warmed with water at 80℃,circumrotated and evaporated until it was nearly dry.Then it was cleaned up by Envi-Carb column and Sep-Pak-NH2 column.The analysis was performed by GC-MS and SIM.Retention time and specific ions were used to confirm the pesticides.Results:The calibration curves of 33 pesticides were linear(correlation coefficient r0.99) within the range of 0.01~1.0 μg/ml.The recoveries were 89%~98%,the relative standard deviations(RSD) of the method was 10% for each case,and the limit of determination(LOD),defined in terms of 3 times baseline noise was 0.001~0.005 mg/kg.Conclusion:The method is suitable for determining pesticides in foods with satisfactory sensitivity,accurcy and precision.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish a method for determination of 33 organophosphorus,pyrethroid,organochlorine,carbamate and weedicide pesticides in foods by gas chromatography-mass spectrometry(GC-MS) and selected ion monitoring(SIM).Methods:The pesticides were extracted with acetone and dichloromethane.The extract was warmed with water at 80℃,circumrotated and evaporated until it was nearly dry.Then it was cleaned up by Envi-Carb column and Sep-Pak-NH2 column.The analysis was performed by GC-MS and SIM.Retention time and specific ions were used to confirm the pesticides.Results:The calibration curves of 33 pesticides were linear(correlation coefficient r0.99) within the range of 0.01~1.0 μg/ml.The recoveries were 89%~98%,the relative standard deviations(RSD) of the method was 10% for each case,and the limit of determination(LOD),defined in terms of 3 times baseline noise was 0.001~0.005 mg/kg.Conclusion:The method is suitable for determining pesticides in foods with satisfactory sensitivity,accurcy and precision.
Key concepts: Chemistry, Chromatography, Selected ion monitoring, Pesticide, Detection limit, Gas chromatography–mass spectrometry, Pyrethroid, Dichloromethane