2010Chinese Journal of Health Laboratory TechnologyRequires access

Determination of multiresidue pesticides in vegetables and fruits by gel-permeation cleanup and gas chromatography/mass spectrometry

Fenghua Li

Open publisher page 0 citations

Abstract

Objective:To establish a method for determination of organophosphorus,carbamate,pyrethroid,organochlorine pesticides in vegetables and fruits by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Methods: The pesticides were extracted with acetonitrile by ultrasonic wave.The extract was cleaned-up by Auto-Gel-Permeation Cleanup(GPC).The analysis was performed by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Retention time and specific ions were used to confirm the pesticides.Results: The calibration curves of 34 pesticides were linear(correlatiom coefficient r0.99) within the range of 0.003 μg/ml~10 μg/ml.The recoveries were ranged from 55.3%~128.1%,the relative standard deviations(RSD) of the method was 20% for each case,and the limit of determination(LOD),defined in terms of 3 times baseline noise was 0.006 mg/kg~0.05 mg/kg.Conclusion: The method is suitable for determining pesticides in fruits and vegetables.

About this research paper

What this paper is about

Objective:To establish a method for determination of organophosphorus,carbamate,pyrethroid,organochlorine pesticides in vegetables and fruits by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Methods: The pesticides were extracted with acetonitrile by ultrasonic wave.The extract was cleaned-up by Auto-Gel-Permeation Cleanup(GPC).The analysis was performed by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Retention time and specific ions were used to confirm the pesticides.Results: The calibration curves of 34 pesticides were linear(correlatiom coefficient r0.99) within the range of 0.003 μg/ml~10 μg/ml.The recoveries were ranged from 55.3%~128.1%,the relative standard deviations(RSD) of the method was 20% for each case,and the limit of determination(LOD),defined in terms of 3 times baseline noise was 0.006 mg/kg~0.05 mg/kg.Conclusion: The method is suitable for determining pesticides in fruits and vegetables.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a method for determination of organophosphorus,carbamate,pyrethroid,organochlorine pesticides in vegetables and fruits by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Methods: The pesticides were extracted with acetonitrile by ultrasonic wave.The extract was cleaned-up by Auto-Gel-Permeation Cleanup(GPC).The analysis was performed by gas chromatography/mass spectrometry(GC/MS) and selected ion monitoring(SIM).Retention time and specific ions were used to confirm the pesticides.Results: The calibration curves of 34 pesticides were linear(correlatiom coefficient r0.99) within the range of 0.003 μg/ml~10 μg/ml.The recoveries were ranged from 55.3%~128.1%,the relative standard deviations(RSD) of the method was 20% for each case,and the limit of determination(LOD),defined in terms of 3 times baseline noise was 0.006 mg/kg~0.05 mg/kg.Conclusion: The method is suitable for determining pesticides in fruits and vegetables.

Key concepts: Chemistry, Chromatography, Selected ion monitoring, Detection limit, Gas chromatography–mass spectrometry, Pesticide, Mass spectrometry, Gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of multiresidue pesticides in vegetables and fruits by gel-permeation cleanup and gas chromatography/mass spectrometry — Research Paper | ScholarLens