Simultaneous Determination of 195 Pesticide Residues in Vegetables Using Solid Phase Dispersive Extraction-Gas Chromatography-Tandem Mass Spectrometry
LI Ron
Abstract
LI Ron
Abstract
Objective: To develop a method for the determination of 195 pesticide residues in vegetables using gas chromatography with tandem mass spectrometry(GC-MS-MS) under a selected reaction monitoring(SRM) mode. Methods: The target compounds were extracted from samples with ethyl acetate and the extract was cleaned up by off-line solid phase dispersive extraction technique. The analytes were quantified by an internal standard method. Results: In the linear range(0.01–1.00 mg/L), the correlation coefficient for each pesticide was higher than 0.99. The average recoveries at three spiked levels(10, 20 and 100 μg/kg) varied from 37.6% to 136.7% with relative standard deviations(RSDs) between 0.2% and 15.3%. The limits of quantification(LOQ)(signal/noise ratio = 10) were 1.9–25.5 μg/kg. Conclusion: The method is rapid, sensitive, accurate and high throughput, without matrix interference and suitable for the analysis of 195 pesticide residues in vegetables.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To develop a method for the determination of 195 pesticide residues in vegetables using gas chromatography with tandem mass spectrometry(GC-MS-MS) under a selected reaction monitoring(SRM) mode. Methods: The target compounds were extracted from samples with ethyl acetate and the extract was cleaned up by off-line solid phase dispersive extraction technique. The analytes were quantified by an internal standard method. Results: In the linear range(0.01–1.00 mg/L), the correlation coefficient for each pesticide was higher than 0.99. The average recoveries at three spiked levels(10, 20 and 100 μg/kg) varied from 37.6% to 136.7% with relative standard deviations(RSDs) between 0.2% and 15.3%. The limits of quantification(LOQ)(signal/noise ratio = 10) were 1.9–25.5 μg/kg. Conclusion: The method is rapid, sensitive, accurate and high throughput, without matrix interference and suitable for the analysis of 195 pesticide residues in vegetables.
Key concepts: Gas Chromatography/Tandem Mass Spectrometry, Chromatography, Chemistry, Solid phase extraction, Pesticide residue, Extraction (chemistry), Analyte, Mass spectrometry